User's Manual
7
Control Box Input Power Voltage Check
Installation Site Power Supply Check
IT’S RECOMMENDED TO HAVE ALL CONTROL BOX ON THE SAME
POWER PHASE,otherwise you need to adjust B sync value step by step
to find a best position to sync different control box connected to power
source with difference phase.
IT’S RECOMMENDED TO HAVE ENOUGH CURRENT SUPPLY FOR
DEACTIVATORS IF THERE ARE MULTIPLE DEACTIVATORS SHARE
ONE POWER SUPPLY. The rated current for Lynx is 3A but the
suggested current draw for one FastPad is 7-8A for better performance, so
a 15 amp power box will better serve 2 deactivators instead of 3 or more.
IT’S RECOMMENDED TO HAVE GOOD GROUNDING FOR POWER
SUPPLY OF DEACTIVATORS. (Some time the poor grounding and high
noise from power supply will decrease the sensitivity or detection range.)
The number on the switch shows which AC input the
system is set to.
In North America, please place the switch at 115;
While in Europe, please place the switch at 230.