User's Manual

24
Key ID “F” – Low Power Deactivation Settings
(default value: 0; valid range: 0-1)
Value Action
0 Normal deactivation strength
1 Low power deactivation for media products
Press [Tx OFF]
Input number for the parameter.
Press [CON] to accept the parameter.
(Inputting “1” will lower the deactivation power for magnetic media products)
Key ID “L” – Alarm Count Reset (default value: 0; valid range: 0-1)
Value Action
0 Initial state, no meaning
1 Reset alarm count
Press [ARM RST]
Input number for the parameter.
Press [CON] to accept the parameter.
(Inputting “1” will reset alarm count to 0)
Key ID “P” - Password Change (default value: 68; valid range: 0-99)
The password can be changed in this mode from the factory default to your
choice. Press the confirm button after input to activate the password.
Note: If you change from the default password, save the new one in a safe
place because if you forget it there will be no way to access the unit.
Low Power Deactivation is strongly recommended
for magnetic media products such as pre-recorded
audio tapes, video tapes, floppy disks, etc.