User's Manual
Common Platform EAS Systems
18
Power Cord Notices
The SPS delivered does not include AC cable for installation; we recommend that you use a
CE approved power cord H05 VV-F or H05 VVH2-F2 (Refer to the Electrical code which
governs your country for installation of an Anti-Theft Unit to the Main power Supply) with the
cable specification and gauge provided below.
North American Power Supply Connections
Here is a sample of qualified external power line at one end with three close
loop lugs connector and a molded receptacle terminal block at the other end.
Conductors are color coded white (neutral), black (line) and green or
green/yellow (ground).
Operation of this equipment at voltages exceeding 130 VAC will require power
supply cords which comply with NEMA configurations.
close loop lugs must attach wires as the following spec
The AC wire into the insulation tube must be
no less than 5mm long.
For North America use of power cords with an AC Plug is not allowed to be
used with the product when permanently installed. Use standard building
wiring as defined by the NEC or CEC.
Also for the North America, conduit size and knockout sizes are called out in UL
60950-1 Annex NAE, Table NAE.2 and Table NAE.3 or the NEC and CEC. (Licensed
electrician should find reference of these requirements from the relative
regulations.)