User's Manual
Pro-Guard & Uni-Guard Installation Manual
19
IR Control Keyboard Function Description & Default Parameters Table
Key ID Button Parameters Description Default Value Valid Range
A GN Gain Adjustment 1 0, 1
B SYN Sync Adjustment 1 0 to 250
C RE Receiving Window Delay 8 0 to 15
H1
Minimum signal adjustment for
antenna Channel 1
H2
MIN
Minimum signal adjustment for
antenna Channel 2
40
0 to 999
(Practical
range 0-200)
D NSE Noise Display (2 channels) 0 0 to 2
F TX OFF Turn off transmitter 1 0 to 1
E DFT Return to default settings 0 0 to 1
P PC Password change 689 (see note) 0 to 999
G ARM OFF Turn off alarm sound 1 0 to 1
L ARM RST Alarm count reset 0 0 to 1
S SA Save the parameters to Flash ROM 0 0-1
CON Confirm the parameters input NA NA
EX Exit NA NA
Note: Default password is 689. After changing, the system will use the new password
as default. The new password will remain saved at power off.