Brochure

29
PCB insertion width Division by Layout schematic reperesentation
up to 64 mm
4 partition walls 400
3 longitudinal rows
64 - 96 mm
4 partition walls 300
3 lateral rows
96 - 107.5 mm
2 partition walls 400
2 longitudinal rows
107.5 - 157 mm
2 partition walls 300
2 lateral rows
157 - 229 mm
1 partition wall 400
233.4 - 235 mm without partition wall
229 - 330.2 mm
1 partition wall 300
333.4 - 335 mm without partition wall
Operating instruction to Printorama System 400 x 300
Instruction
1. Measure the insertion (dimension) width of the PCB
(partition wall 400 or 300) on page 30.
4. Read the scale number and plug-in the chosen partition
2. Determine the optimum utilization possibilities of available
space by means of the table shown below.
wall at the corresponding scale number.
Example
1. Insertion width measured on the circuit board = 210mm.
2. Optimum utilizarion of available space in accordance with the
table shown below: 1 longitudinal row with partition 400
3. The next higher dimension is 210.83mm in the column 400
3. Find the next higher size in the corresponding column
partition wall, minus distance at scale number 19 (page 30).
4. Plug-in partition wall 400 minus distance version at scale
number 19.
Optimum space utilization in Printorama System 400x300
1 longitudinal row
1 lateral row
PCB insertion width Division by Layout schematic reperesentation
up to 96 mm
4 partition walls 600
3 longitudinal rows
96 - 157 mm
2 partition walls 600
2 longitudinal rows
157 - 164.5 mm
4 partition walls 400
3 lateral rows
164.5 - 257 mm
2 partition walls 400
2 lateral rows
257 - 325 mm
1 partition wall 600
333.4 - 335 mm without partition wall
325 - 529 mm
1 partition wall 400
533.4 - 535 mm without partition wall
Operating instruction to Printorama system 600x400
Instruction
1. Measure the insertion (dimension) width of the PCB
(partition wall 400 or 600) on page 30.
4. Read the scale number and plug-in the chosen partition
2. Determine the optimum utilization possibilities of available
space by means of the table shown below.
wall at the corresponding scale number.
Example
1. Insertion width measured on the circuit board = 375mm.
2. Optimum utilizarion of available space in accordance with the
table shown below: 1 lateral row with partition 400
3. The next higher dimension is 375.42 mm in the column 400
3. Find the next higher size in the corresponding column
partition wall, normal distance at scale number 22 (page 30).
4. Plug-in partition wall 400 normal distance version at scale
number 22.
Optimum space utilization in Printorama system 600x400
1 longitudinal row
1 lateral row