Technical Specifications
February 2018 • Reorder OSB-4000
, Weyerhaeuser, Trus Joist and Down Pore are registered trademarks and Edge,
Edge Gold, and TJ-Pro are trademarks of Weyerhaeuser NR.
© 2018 Weyerhaeuser Company. All rights reserved. Printed in the USA.
This document supersedes all previous versions. If this is more than
one year old, contact your dealer or Weyerhaeuser rep.
CONTACT US
1.888.453.8358 • weyerhaeuser.com/woodproducts/contact
Contact your local representative or dealer at:
Visit weyerhaeuser.com/woodproducts/warranty for copies of these and other Weyerhaeuser product warranties.
Edge
™
and Edge Gold
™
panels are
intended for dry-use applications
No sanding. No delamination. We guarantee it.
woodbywy.com
DOWN PORE
SELF-DRAINING
TECHNOLOGY
□
5
⁄
8
" panels –
54 pcs
– Max span 20" o.c.
□
2
3
⁄
32
" panels – 48 pcs – Max span 24" o.c.
□
7
⁄
8
" panels – 39 pcs
– Max span 32" o.c.
□
1
1
⁄
8
" panels – 30 pcs – Max span 48" o.c.
□
47
1
⁄
2
" net width
□
48" net width
□
Other specs __________
Installation
Instru
ctions
■
Floor should be insta lled a s
a glue-nailed system , using a
construction adhesi ve that
meets the requiremen ts of
ASTM D 3498 (AFG-01).
■ Apply a
¼
" diameter (or larger )
bead of adhesive alon g the to p
of the joist flange; u se two
beads where panel edg es meet .
■ Install panels with the lo ng
dimension across supp orts.
If panels are cut, ens ure tha t
a minimum of two spans are
covered.
■ Gap panel ends
⅛
". A 10d box
nail can be used to gau ge the
gap. Tongue and groove e dges
are self-gapping.
■ Nail the floor in pla ce befo re
the glue sets, followi ng the
adhesive manufacture r's
instructions for allo wable cure
time. Locate nails ⅜
" from
panel e
dges.
For
2
3
⁄
32
" panels, use
6d (2") deformed shan k or
8d (2
½
") common nails.
For ⅞
" and 1⅛
" panels, use
8d (2
½
") deformed shank or
8d (2
½
") common nails.
Screws may be substitu ted
for nails noted above i f the
screws have equivalen t
capacity.
Drape plastic over top and
sides. Allow air circulation.
Nail plastic
to top
Drape plastic over
each end and hold
down with 2x4
Like any wood product, wood-based panels are at risk of fungal decay or rot if
exposed to repeated wetting or high-moisture environments. Panels that are
exposed to such conditions may deteriorate, lose strength, or support mold growth,
so protection from these conditions must be provided.
Use a platform made from cull panels and scrap lumber supported by stickers
that extend across the width of the stack, and keep panels at least 4" from the
ground. Put one sticker in the center of the load and the others approximately 12"
from each end. When covering the panels, drape plastic over the ends of the stack
and secure it. Then drape plastic over the top and sides of the stack; stake it to
the ground, pulling the ends away from the product to allow air circulation along
the sides of the stack.
Handle Edge
™
and Edge Gold
™
panels in a flat orientation. Protect the edges and
ends from damage, keep the load level, and lift the stack from the center.
WARNING: Drilling, sawing, sanding or machining wood products generates wood
dust. The paint and/or coatings on this product may contain titanium dioxide.
Wood dust and titanium dioxide are substances known to the State of California
to cause cancer. For more information on Proposition 65, visit wy.com/inform.
Exposure 1 Bond Classification
Edge
™
and Edge Gold
™
panels are manufactured to an Exposure 1 bond
classification. Exposure 1 panels are suitable for uses where they are not
permanently exposed to the weather; they are intended to resist the effects of
moisture on structural performance due to construction delays or other conditions
of similar severity.
PRODUCT WARRANTIES
PRODUCT STORAGE AND HANDLING