Specifications
10/31/02 Tech-304/DWO 14195 Page 31 of 39
Appendix B
Procedure to Remove Display Board and Electronic Canister
1. Remove the three screws that fasten the display board. (See Figure Below).
2. Gently pull up the display board disconnecting the board from the 30-pin connector on the
upper right corner of the display board.
3. Gently remove the transducer pin connector. Be careful not to pull any of the wires out of
the connector.
4. Gently remove the hall effect sensor pin connector. Be careful not to pull any of the wires
out of the connector.
5. At this point the display board is completely disconnected. If the electronic canister is to be
removed, it can be done so by removing the three screws that fasten it to the housing.
Screws
30 - Pin
Connector
Display Board
(Shaded Area)
Screw
Hall Effect
Sensor Pin
Connector
Transducer
Pin Connector