User Manual
42 43INSTALLATION INSTALLATION
WARNING
WARNING
To avoid any potential hazard, you must follow our 
instructions when you install your appliance. Failure 
to install the appliance correctly could invalidate any 
warranty or liability claims and lead to prosecution.
•   This appliance must be installed by an authorised 
person according to all codes and regulations as 
stated in the local municipal building code and other 
relevant statutory regulations.
•   Wiring connections must be in accordance with AS/ 
NZS 3000 Wiring Rules and any particular conditions 
of the local authority.
•   Refer to data plate for rating information. The data 
plate is positioned behind the bottom of the oven 
door. 
•   Disconnection in the fixed wiring must occur in 
accordance with the AS/NZS3000 wiring rules.
•   Wiring should be protected against mechanical 
failure. Refer to AS/NZS3000 clauses 3.3.2.6, 3.9, 3.10
•   A means of disconnection with a contact separation 
of at least 3mm must be supplied in the fixed wiring.
•   This range must be connected with cable of 75°C 
rating minimum.
•   This product has passed the insulation resistance test 
after manufacture. If the resistance reading is low at 
installation, it is probably caused by moisture from 
the atmosphere being absorbed by the elements 
after the range has been produced. (Pass at 0.01MΩ 
AS/NZS 3000 Wiring Rules Clause 8.3.6.2).
Rated power input
MODEL TOTAL kW A1 kW A2 kW
WVE645 8.7 2.3 6.4
WARNING
WARNING
This appliance must be properly earthed.
•   Do not lift the appliance by the door handles.
•   Prepare the cupboard opening to match your 
appliance measurements. (See diagrams)
•   Slide appliance into the cupboard, ensuring that the 
supply cable (where fitted) does not kink.
•   To prevent tipping, use the screws supplied to secure 
your oven into the cupboard. Use just 2 screws for 
underbench and separate grill underbench ovens, and 
4 screws for separate grill wall ovens. Remove the 
bottom door in separate grill wall ovens to provide 
access to the bottom 2 screwing points.
•   For appliances fitted with a flexible supply cord, if 
the cord is damaged, it must be replaced by the 
manufacturer or its service agent or similarly qualified 
person in order to avoid a hazard. The plug must be 
accessible after installation.
•   Where the appliance is built into a cabinet, the 
cabinet material must be capable of withstanding 
70°C. Installation into low temperature tolerant 
cabinetry (e.g. vinyl coated) may result in 
deterioration of the low temperature coating by 
discolouring or bubbling.
•   If the appliance is installed adjacent to vinyl-wrapped 
surfaces, use an installation kit available from the 
vinyl-wrap supplier.
•   Electrolux Home Products cannot accept 
responsibility for damage caused by installation into 
low temperature tolerant cabinets.
•   After installation, test and ensure that the appliance 
operates correctly before handing it over to the 
customer. It is recommended that this product is not 
installed in an unvented living space, particularly if 
that space incorporates sleeping quarters.
INSTALLING YOUR APPLIANCE
MODEL
PRODUCT 
DIMENSIONS
(H X W X D) MM
MINIMUM FUSE 
RATING
MAXIMUM 
POWER RATING
MAXIMUM 
CURRENT RATING
WIRE 
SECTION 
(MM²)
WVE613 597 x 596 x 573 16A 2.3kW 9.6A 2.5
WVES613 597 x 596 x 573 16A 2.3kW 9.6A 2.5
WVE614 597 x 596 x 573 16A 2.3kW 9.6A 2.5
WVE615 597 x 596 x 573 16A 3.0kW 12.5A 2.5
WVE616 597 x 596 x 573 16A 3.0kW 12.5A 2.5
WVEP615 597 x 596 x 573 16A 3.1kW 12.9A 2.5
WVE617 597 x 596 x 573 16A 3.1kW 12.9A 2.5
WVEP618 597 x 596 x 573 16A 3.1kW 12.9A 2.5
WVE626 890 x 596 x 573 25A 5.3kW 22.4A 4.0
WVE636 1083 x 596 x 573 32A 6.2kW 25.8A 6.0
WVE645 597 x 596 x 573 40A 8.7kW 36.3A 6.0
WVE655 727 x 596 x 573 25A 4.9kW 20.4A 4.0
WVE665 890 x 596 x 573 25A 5.3kW 22.1A 4.0
WVE607 597 x 596 x 573 16A 3.1kW 12.9A 2.5
Note: Electrical connection is 230-240 volts AC 50Hz. Wiring minimum temperature rating 75°C.
•   If a powerpoint is fitted it must be accessible with the 
appliance installed, as the plug must be accessible 
after installation.
•   This appliance must be mounted on a flat surface for 
the full width and depth of the product.
•   To avoid overheating, the appliance must not 
be installed in a recess or cupboard behind a  
decorative door.
Hard wiring detail
1.   Remove terminal cover plate from rear panel  
of appliance.
2.   Fit wires through hole in cover plate and make 
connections to terminals.
3.   Engage wires into plastic clip. Secure plastic clip with 
two long silver screws (supplied in separate bag).
4.  Replace cover plate onto rear panel.
553mm
15mm
A
8mm min 
clearance
Second active wire only 
required (optional) for 
multi-phase products
Plastic clips
Plastic clip 
securing points
Cabinet construction for your appliance
For the best integration within a kitchen, install the 
appliance in a standard 600mm wide cupboard that gives 
a flush fit with the surrounding cupboard fronts as shown 
in Fig. A. A recess of 20 mm is ideal. 
With the exception of pyrolytic ovens, the appliance can 
also be installed using a proud fit to the surrounding 
cupboard as shown in Fig. B.
WARNING
CAUTION
For all Pyrolytic clean oven models, the oven must be 
installed as a flush fit to the surrounding cupboards and 
the “Infill panel” MUST not exceed 100mm in length. This 
ensures a 16mm gap is maintained between the cabinet 
and oven side to prevent the cupboard overheating.
Fig. A
Flush Fit
16mm
568mm
600mm
20mm
Infill 
panel
Cupboard 
door
Oven
100mm max 
for Pyro oven
Fig. B
Proud Fit
16mm
568mm
600mm
Infill 
panel
Cupboard 
door
Oven
100mm max 
for Pyro oven