6 INSTALLING YOUR APPLIANCE
If a powerpoint is fitted it must be accessible with the
appliance installed, as the plug must be accessible
after installation.
This appliance must be mounted on a flat surface for
the full width and depth of the product.
To avoid overheating, the appliance must not
be installed in a recess or cupboard behind a
decorative door.
Hard wiring detail
1. Remove terminal cover plate from rear panel
of appliance.
2. Fit wires through hole in cover plate and make
connections to terminals.
3. Engage wires into plastic clip. Secure plastic clip with
two long silver screws (supplied in separate bag).
4. Replace cover plate onto rear panel.
553mm
15mm
A
8mm min
clearance
Second active wire only
required (optional) for
multi-phase products
Plastic clips
Plastic clip
securing points
Cabinet construction for your appliance
For the best integration within a kitchen, in stall this
appliance in a standard 600mm wide cupboard that
gives a flush fit (FigureA) with the surrounding cupboard
fronts. Appliances can also be installed using a proud fit
(Figure B).
WARNING
CAUTION
For all Pyrolytic clean models, the “infill panel” MUST
not exceed 100mm in length. This ensures a 16mm
gap is maintained between the cabinet and side of the
appliance to prevent the cupboard overheating. Cabinet
must be minimum 600mm width.
Fig. A
Flush Fit
16mm
568mm
600mm
20mm
Infill
panel
Cupboard
door
Oven
100mm max
for Pyro
oven
Fig. B
Proud Fit
16mm
568mm
600mm
Infill
panel
Cupboard
door
Oven
100mm max
for Pyro
oven
Levelling oven
Place a level in the oven as below, making sure the level
sits on the front and rear forms.
INSTALLING YOUR APPLIANCE (CONTINUED)