User manual
using economy options, however the water
temperature must not exceed 60 °C.
Inlet water supply
• Water pressure: 800 kPa max - 50 kPa
min.
• Water flow rate 10 L / minute min.
• If water pressure is in excess of 800 kPa,
a pressure reducing valve should be
used. Check for leaks.
• If water temperature is in excess of 60
°C, a tempering valve should be used.
Check for leaks.
Caution! Always use new hoses when
you connect the appliance to the water
mains. Old hoses must not be used.
The water inlet hose must be examined
at an interval of twelve months for
deterioration and replaced if necessary.
The water pressure must be in the limits,
refer to “TECHNICAL INFORMATION”.
Make sure that the local water authority
gives you the average mains pressure in
your area.
Water drain hose
The highest point of the drain hose must be
no more than 600 mm from the floor and
must have a continuous fall to the plumbing
connection.
The drain hose can be lengthened using
additional lengths and connectors. These
must be purchased from Electrolux Spare
Parts. The extension length must not ex-
ceed 2 metres.
The drain hose must be free of obstruc-
tions.
Remove the sink plug when the appliance
drains the water to prevent that the water
goes back into the appliance.
The appliance has a security feature to pre-
vent dirty water going back into the appli-
ance. If the spigot of the sink has a non-re-
turn valve, this valve can cause the appli-
ance to drain incorrectly. Remove the non-
return valve.
Remove
entire
internal
membrane
If you connect the water drain hose to a
trap spigot under the sink, remove the
plastic membrane. If you do not remove the
membrane, remaining food can cause a
blockage in the drain hose spigot.
westinghouse 17