Recommended installation sequence
External exhaust mode installation
F1
D
1
1 X
S T 2 . 9*9. 5
1(optional)
2
3
C
1
8X
WOOD SCREWS Φ4*30
WALL PLUG Φ6
D
1-1
D
1-
E1-1
E1
* Leave 3mm
gap between
screw head and wall
Diagram C1
• Install cooker hood body. Determine working
height, mark wall to suit. Install flue cover mounting
brackets.
• Ensure the screws highlighted in “C1” have 3mm
gap between screw head and wall, this will ensure
sufficient space for flue cover fitment.
Diagram(s) D1
Fix flue transition to cooker hood body.
o Put the non-return flap (“1”) in the outlet of the product (“3”)
o Fasten the non-return valve with the screw supplied to
ensure the non-return valve is securely fastened. (D1-1)
o Loosen the hose clamp (“2”) and put it outside of “3”
o Fit the flue over the outer wall of “3”
o Tighten the hose clamp through the side hole with a
screwdriver (D1-2)
Diagram(s) E1
Install bottom section of telescopic flue cover
Diagram F1
Install top section of telescopic flue cover
and fasten the cover with supplied screws