User Manual

INSTALLATION
4
INSTALLATION
Plastic clip
Plastic clip
securing points
WARNING
WARNING
This appliance must be installed by an authorised person in
compliance with local municipal building codes and any
other relevant statutory regulation.
Wiring connections must be made in accordance with:
New Zealand & Australian requirements, including
AS/NZS 3000 WIRING RULES.
Refer to data plate for rating information. The data plate is
positioned on the bottom of the oven front, viewable with
the oven door open.
Electrical connection is 230–240 volts AC 50 Hz.
To gain access to the mains connection terminals, remove
the rear cover by unscrewing the two assembly screws.
The cooker requires a means of all pole disconnection
incorporated into the fixed wiring. This MUST have a
disconnection gap of 3mm.
The cooker MUST be earthed. Any damage caused by
failure to earth will not be covered by warranty.
This range must be connected with cable of 75°C
rating minimum.
This product has passed the insulation resistance test
after manufacture. If the resistance reading is low at
installation, it is probably caused by moisture from the
atmosphere being absorbed by the elements after the
range has been produced. (Pass at 0.01MΩ AS/NZS
3000 Wiring Rules Clause 8.3.6.2).
NOTE: Where connection is made to a multi-phase
220/240V supply, the bridge piece must be removed from
between the active connections on the main terminal block.
Fuse (for New Zealand only)
Should the fuse need servicing it is accessible through the
fuse opening located in the back cover. The Cooking range
must be connected to the supply by a supply cord fitted
with the appropriately rated plug with the socket-outlet fitted
to the final sub-circut in the fixed wiring that is intended to
supply this cooking range. See table below.
Supply cord specifications
MODEL CURRENT
RATING
(AMPS)
WIRE
SECTION
(MM
2
)
MINIMUM
TEMP
RATING (°C)
WLE620WA
25 2.5 75
WLE622WA
32 4.0 75
WLE624WA
32 4.0 75
WLE625WA
32 4.0 75
WLE626WA
32 4.0 75
WLE644WA
32 4.0 75
WLE645WA
32 4.0 75
WLE646WA
32 4.0 75
Hard wiring detail
1. Remove terminal cover plate from rear panel
of appliance.
2. Fit wires through hole in cover plate and make
connections to terminals.
3. Engage wires into plastic clip. Secure plastic clip with
two long silver screws (supplied in separate bag).
4. Replace cover plate onto rear panel.
Rated Power Input
MODEL TOTAL kW A1 kW A2 kW
WLE620
9.7 3.1 6.6
WLE622
11. 7 5.1 6.6
WLE624
12.1 5.5 6.6
WLE625
10.7 4.1 6.6
WLE626
12.1 5.5 6.6
WLE644
11. 4 5.0 6.4
WLE645
10.5 4.1 6.4
WLE646
11. 8 5.4 6.4