MAINTENANCE
CLEANING/REPLACING THE AIR FILTER
See Figure 22.
Keep air lter clean. A dirty air lter can cause poor perfor-
mance and decrease the service life of the product. NEVER
operatethegeneratorwithoutanairlterinplace.
l Turn the generator off and allow the engine to cool for
30minutes.
l Remove the air lter from the air cleaner housing and
place it in a suitable cleaning container. Replace the air
lterifdamaged.
NOTE: The air lter may be covered in oil. Use an appro-
priate container.
l Wash the air lter by submerging the lter in a solution
of household detergent soap and warm water. Slowly
squeeze the lter to thoroughly clean.
NOTICE
DO NOT twist or tear the air lter during
cleaning or drying. Only apply slow but rm squeezing
action.
l Rinse the air lter by submerging it in fresh water and
applying a slow squeezing action. Allow the lter to dry
thoroughly.
NOTICE
Do not pollute. Follow the guidelines
of the EPA or other governmental agencies for proper
disposal of hazardous materials. Consult local author-
ities or reclamation facility.
l Dip the air lter in clean engine oil then squeeze out all
excess oil. The engine will smoke when started if too
much oil is left in the lter.
l Install the air lter in the air cleaner housing and reinstall
the air lter cover.
CHANGING THE ENGINE OIL
See Figure 23.
For optimal performance, change the engine oil according
to the gures specied in the maintenance schedule or
the engine manual (if applicable). When using the generator
under extreme, dirty, dusty conditions or in extremely hot
weather, change the oil more frequently.
NOTE: Change the oil while the engine is warm but not
hot. Warm engine oil drains more quickly and thoroughly
than cool oil. Contact with hot oil will cause serious burns.
l
Turn the generator off and allow the engine to cool for
30minutes.
l Place the generator on a level surface in a well-ventilated
area.
l Clean the area around the oil dipstick and drain bolt.
A - Air filter cover
B - Air filter
C - Latch
D - Air filter box
C
B
A
FIG. 23
A - Oil dipstick/filter
B - Drain bolt
C - Oil fill
A
D
B
FIG. 22
C
l Slowly unscrew and remove the oil dipstick.
l Place an oil pan (or suitable container) under the generator.
l Remove the drain bolt.
l After the oil has drained completely, replace the drain
bolt.
l Rell the oil as described in the Operations section.
l Clean the oil dipstick.
l Replace the oil dipstick and hand-tighten.
l Clean up any spilled oil.