Westinghouse Portable Power | 21
OPERATION
STARTING THE GENERATOR
1. Move generator to a at surface outside in a well
ventilated area.
2. Check oil levels (see Adding Engine Oil page 24).
3. Verify the battery is installed and both battery
cables are attached to their corresponding polarity.
See Installing the Battery on page 12.
4. Disconnect all electrical loads from the generator.
5. Make sure the circuit breakers are properly set (see
Figure 8 below).
240/120VMain Circuit Breaker Operating Position
240/120V Main Circuit Breaker Tripped Position
120V Circuit Breaker Operating Position
120V Circuit Breaker Tripped Position
4. Select fuel source for start up:
FOR GASOLINE:
a. Move the fuel shut o valve to the ON position
(see Figure 9).
b. Turn fuel selector knob to GASOLINE (see
Figure 9).
Figure 9 - Fuel Shut O - ON
Fuel Selector - GASOLINE
FOR LPG/PROPANE:
a. Make sure the LPG hose is safely secured from
the generator to the tank (see Connecting the
LPG Tank on page 19).
b. Turn the fuel selector knob to PROPANE (see
Figure 10).
c. Fully open the valve on the propane tank.
5. Switch the engine switch to RUN (see Figure 11).
6. Choose starting method:
a. Recoil Start: Move the choke to the right then
rmly grasp and pull the recoil handle slowly
until you feel increased resistance. At this point,
apply a rapid pull while pulling up and slightly
away from the generator.
b. Remote Start: Click START on the wireless key
FOB provided.
c. Push Button Start: Push and hold the engine
start push button for 1 second and release.
• The engine will automatically set the choke and begin the
start sequence.
• If the engine has started successfully the light indicator
on the engine start button will turn green.
• If the engine fails to start, the generator controls will
attempt to start the engine two more times for a total of
three attempts.
• If the third attempt fails, the light on the engine start
button will turn red.
• If the engine has failed to start after three attempts the
engine start button can be pushed again to begin the
automatic start sequence.
• The red engine stop button can be pushed at any time
during the automatic start sequence to abort the engine
start attempt.
OPERATION
Figure 8 - Breakers
Figure 10 - Fuel Selector - PROPANE
Propane Tank Valve - OPEN
Figure 11 - Engine Switch - RUN
1
2
3
4
ON
OFF