User's Manual

25INSTALLATION
The cooker MUST be installed in compliance with:
Wiring connections in AS/NZS 3000 Wiring Rules
Local regulations, municipal building codes and other
statutory regulations
For New Zealand Only:
The cooking range must be connected to the supply
by a supply cord fitted with the appropriately rated
plug that is compatible with the socket-outlet fitted
to the final sub-circuit in the fixed wiring that is
intended to supply this cooking range.
Data plate gives information about rating
is located behind the bottom of the
oven door
A functional switch MUST be provided near the
appliance in an accessible position (AS/NZS 3000 -
Clause 4.7.1).
Wiring MUST be protected against mechanical failure
(AS/NZS 3000 - Clause 3.9).
The cooker requires a means of all pole disconnection
incorporated into the fixed wiring. This MUST have a
disconnection gap of 3mm.
The cooker MUST be properly earthed.
This range must be connected with cable of 75°C
rating minimum.
This product has passed the insulation resistance test
after manufacture. If the resistance reading is low at
installation, it is probably caused by moisture from
the atmosphere being absorbed by the elements
after the range has been produced. (Pass at 0.01MΩ
AS/NZS 3000 Wiring Rules Clause 8.3.6.2).
NOTE: When connections are made to a multi-phase
230/240V supply, the bridge piece MUST be removed
from between the active connections.
TIPS & INFORMATION
TIPS AND INFORMATION
Before you cook in your new oven it is important that
the protective oils used in the manufacture of the
product be removed.
Make sure that the room is well ventilated (to allow
smoke to escape).
New appliances can have an odour during first
use. It is recommended to ‘run in’ the oven
before cooking for the first time Operate the
oven(s), empty, at a temperature of 18C for
approximately 30 minutes. For appliances with
a separate grill, run the grill on maximum for 15
minutes WITH GRILL DOOR OPEN Please ensure
that the room is well ventilated during this process.
CONNECTING TO SERVICES AND
COMMISSIONING
WIRING REQUIREMENTS
This appliance must be installed by an authorised person,
according to all codes and regulations of:
Electrical supply authorities.
Building regulations.
Local government and council authorities.
AS/NZS 5601.1 (particular attention to clause 6.10.1
and figure 6.3 on page 97, and clause 6.10.1.11).
AS/NZS 3000 (particular attention to clause 4.7.1
and clause 3.9).
Electrical supply connection
WFE619 and WFE517 models are fitted with
a 20-Amp service cord.
WFE616 and WFG617 models are fitted with
a 10-Amp service cord.
Hard wiring detail (WFE547, WFE642 and WFE647
models only)
1. Remove terminal cover plate from rear panel of
appliance.
2. Fit wires through hole in cover plate and make
connections to terminals.
3. Engage wires into plastic clip. Secure plastic clip with
two long silver screws (supplied in separate bag).
4. Replace cover plate onto rear panel.
Plastic clips
Plastic clip
securing points
RATED POWER INPUT
MODEL TOTAL
WATTAGE
(KW)
TOTAL
CURRENT
(AMPS)
CABLE
SECTION
(MM2)
MINIMUM
TEMPERATURE
RATING (°C)
WFE642 8.7 36.3 2.5 75
WFE647 10.5 43.8 4.0 75
WFE547 10.5 43.8 4.0 75
MODEL TOTAL KW A1 KW A2 KW
WFE547 10.5 4.1 6.4
WFE642 8.7 2.3 6.4
WFE647 10.5 4.1 6.4