User Manual
10 11CONNECTIONSCONNECTIONS
CONNECTIONS
Wiring connection for gas cooker
To allow for disconnection of the appliance after 
installation, the plug must be accessible after installation. 
If the supply cord is damaged, it must be replaced by 
the manufacturer, its service agent or similarly qualified 
persons in order to avoid a hazard.
Installing the gas cooker gas connection
Read these points before connecting to the gas supply:
•   The cooker inlet connection point has a ½” BSP 
external thread. See diagram below.
•   An NG regulator or a LPG/Propane test point fitting 
is supplied.
•   It is recommended to fit the regulator or test point 
fitting to the appliance connection point, then fit 
either hard piping or a high level flexible connection 
(AS/NZS 5601.1 clauses 5.9 and 6.10.1.9) which is then 
attached to the consumer hard piping.
•  Ensure installation allows withdrawal of appliance.
Restraining device 
anchor points
Gas connection 
point
650mm
175mm
Operation on universal LPG/propane
1.   The appliance inlet fitting provided MUST be 
orientated so that the pressure nipple is accessible.
2.   The inlet fitting has ½” BSP internal thread at the inlet 
  and outlet.
Gas requirements
This appliance must be installed by an authorised person, 
according to all codes and regulations of:
AS/NZS 5601.1 (particular attention to clause 6.10.1, figure 
6.3, and clause 6.10.1.11.)
•  The cooker models WFE512, WFE614, WFE612 and 
WFE616 come in two gas types – Natural gas and 
Universal LPG. 
•  Model WFG612SC comes in two gas types – Natural 
Gas and Propane. Model WFG612WC only comes in 
Natural Gas.
Before installation check that the cooker is suitable for 
the gas supply. To do this check the gas type on the 
carton sticker or on the data plate behind the bottom of 
the oven door. The following table shows the supply and 
operating pressures for various gas supplies.
GAS TYPE NATURAL 
GAS
UNIVERSAL 
LPG
PROPANE
Supply pressure 
at inlet to 
appliance 
regulator (if 
fitted)
1.13kPa 
minimum
2.75*kPa 2.75*kPa
Operating 
pressure at 
appliance 
test point for 
WFG612
1.00kPa – 2.75kPa
Operating 
pressure at 
appliance 
test point 
for WFE512, 
WFE614, WFE612 
& WFE616
1.00kPa 2.60kPa –
*Some models do not require an appliance regulator 
for LPG or Propane operation, in which case the supply 
pressure and operating pressure are the same. In such 
cases the supply pressure is adjusted at a regulator in the 
consumer piping, typically located at the cylinder. 
Models WFE512, WFE614, WFE612 & WFE616
The following table shows the injector sizes for each 
burner.
INJECTOR ORIFICE NATURAL 
GAS
UNIVERSAL 
LPG
Low heat burner 1.00mm 0.55mm
Medium heat burner 1.35mm 0.70mm
High heat burner 1.60mm 0.90mm
Operation on SNG (WFG612 models only)
•   If the cooker is to be used with SNG, then the grill 
burner MUST be modified by the replacement of the 
shutter, which fits into the throat of the grill burner.
•   A conversion kit can be obtained by contacting the 
Customer Care Centre.
Restraining Device
Anchor Points
Connection
Gas
Point
150mm
650mm
Grill shutter
Grill deflector
WARNING
 WARNING
Disconnect electric power before removing control panel.
1.  Remove the control panel.
2.   Remove the 2 screws from grill deflector (refer to 
diagram above)
3.   Remove the existing NG shutter securing screw (refer 
to diagram above) and slide upwards to disengage 
from grill burner.
4.   Slide the SNG shutter into position and secure 
with screws.
Testing the gas cooker
WARNING
 WARNING
You MUST test the cooker after installation, before you 
hand it over to the customer.
You MUST have a manometer and a connecting tube.
Intense heat wok burner 1.75mm 1.00mm
Models WFG612
The following table shows the injector sizes for each 
burner.
INJECTOR ORIFICE NATURAL 
GAS
PROPANE
Low heat burner 1.00mm 0.62mm
Medium heat burner 1.35mm 0.82mm
High heat burner 1.60mm 0.95mm
Intense heat wok burner 1.75mm 1.00mm
Oven – main injector 1.60mm 0.95mm
Grill 1.50mm 0.82mm
Oven – bypass screw 0.73mm 0.45mm
Checking pipe size
To work out a suitable pipe size for connection use:
•  The information in this table.
GAS TYPE NATURAL 
GAS
UNIVERSAL 
LPG
PROPANE
Hourly gas 
consumption for 
WFG612
63.3MJ/h – 61.5MJ/h
Hourly gas 
consumption 
for WFE614, 
WFE612 & 
WFE616
40.4MJ/h 34.4MJ/h –
Hourly gas 
consumption for 
WFE512
37.3MJ/h 30.2MJ/h –
•  Information about the length of the run, number 
of elbows, tees and bends, the available service 
pressure and the supply requirements, AS/NZS 
5601.1 will help you with this matter.