User Manual
LPG CONVERSION DONG YANG – IMPORTANT  
(MODELS WFE512, WFE614, WFE612 AND WFE616 ONLY)
This appliance is fitted with Natural Gas burner injectors.
Please follow the procedure below if a conversion to suit 
UNIVERSAL LPG is required.
The conversion kit contains 5 injectors and 1 LPG sticker.
1.   Remove the hotplate burners to access the hotplate 
injectors. Replace the factory fitted NG injectors with 
the appropriate injectors, as supplied.
2.   Unscrew the hex nut from the regulator. The hex 
nut, brass washer and nylon insert will disengage  
as an assembly.
3.   Unclip the nylon insert from the nut assembly by 
rotating the insert 1/4 turn, and pulling it free.
4.  Turn over the insert, and clip back into position.
5.   Refit the hex nut assembly to the regulator ensuring 
that it is fully screwed down. The regulator is now set 
for connection to LPG.
6.   Turn on the gas supply and at each new connection 
check for leaks using soapy water: each hotplate 
valve should be turned on, one at a time, and the 
injector hole blocked off for several seconds.
7.   The operation of the regulator can be confirmed by 
connecting a manometer to the pressure test point 
located on the side of the regulator body adjacent 
to the outlet. With the appliance operating check the 
outlet pressure:
  •   When all burners of the appliance are operating 
at maximum,
  •   When the smallest burner of the appliance is 
operating at minimum.
   Under these conditions the outlet pressure should not 
vary from the nominal outlet pressure of 2.60kPa by 
more than ±0.52kPa.
8.   If the regulator appears to not be performing 
satisfactorily then check the following points:
  •   If the outlet pressure is consistently too low then 
the inlet pressure may be too low and 
adjustment of an upstream regulator may be 
needed, or an upstream regulator or valve with 
insufficient flow capacity may be present in 
the gas supply line. If this is suspected then it 
may be necessary to repeat the checks whilst 
measuring both the inlet and outlet pressure to 
determine if the inlet pressure is in the range  
2.75 – 7.00kPa.
  •   Check that the insert has been fitted correctly. 
  •  Check that the turret screw is fully screwed down.
  •   Check that the regulator has been fitted to 
the gas supply line in the correct orientation, 
the arrow on the base of the body indicates the 
direction of gas flow.
   Once these checks have been completed, if the 
regulator still fails to perform in a satisfactory manner 
it should be replaced.
9.   One by one, turn the knobs to minimum and screw 
in the bypass screw (accessible when the knob is 
removed) until a small stable flame results. Turn the 
knob to maximum and then back to minimum to 
ensure that the correct minimum flame is maintained.
10.   Attach the LPG sticker to the cooker, near the gas 
supply inlet. Cover the Natural Gas label that is
factory fitted.
Hex nut assembly,  
fully screwed down
Hex nut assembly,  
removed from 
regulator and insert 
disassembled
Insert oriented for 
Natural Gas operation
Insert oriented for 
LPG operation
LPG CONVERSION CHANT – IMPORTANT 
(MODELS WFE512, WFE614 AND WFE612 AND WFE616 ONLY)
This appliance is supplied set up for Natural Gas usage. 
A conversion kit is included with the product for Universal 
LPG usage. The conversion kit contains 5 injectors and 1 LPG 
sticker.
Please follow the procedure below if a conversion to suit 
UNIVERSAL LPG is required:
1.   Remove the hotplate trivets, burner caps and burner 
crowns to access the hotplate injectors. Replace the 
factory fitted injectors with the appropriate injectors, as 
supplied. Refer to injector orifice table for injector sizes. 
The injector size is stamped on the side of the injector.
2.   Unscrew the top hat nut from the regulator. The top hat 
nut and control pressure spring assembly will disengage 
as an assembly.
3.   Unscrew the threaded pin from top hat.
4.   Upturn threaded pin, so spring is free and screw pin 
back into the top hat until firm.
5.   Refit the top hat nut assembly to the regulator ensuring 
that it is fully screwed down. The regulator is now set 
for connection to LPG.
6.   Turn on the gas supply and at each new connection 
check for leaks using soapy water. Each hotplate valve 
should be turned on, one at a time, and the injector hole 
blanked off for several seconds.
7.   The operation of the regulator can be confirmed by 
connecting a manometer to the pressure test point 
located on the side of the regulator body adjacent to 
the outlet.
With the appliance operating check the outlet pressure:
  •   When all burners of the appliance are operating 
  at maximum,
  •    When the smallest burner of the appliance is   
operating at minimum.
   Under these conditions the outlet pressure should not 
vary from the nominal outlet pressure of 2.60kPa by 
more than ±0.52kPa.
8.   If the regulator appears to not be performing 
satisfactorily then check the following points:
  •   If the outlet pressure is consistently too low then
the inlet pressure may be too low and adjustment 
of an upstream regulator may be needed, or an 
upstream regulator or valve with insufficient flow 
capacity may be present in the gas supply line. 
If this is suspected then it may be necessary to 
repeat the checks whilst measuring both the 
inlet and outlet pressure to determine if the inlet 
pressure is in the range 2.75 – 7.00kPa.
  •  Check that the insert has been fitted correctly.
  •   Check that the turret screw is fully screwed down.
  •    Check that the regulator has been fitted to the gas 
supply line in the correct orientation, the arrow on 
the base of the body indicates the direction of gas 
flow.
Once these checks have been completed, if the 
regulator still fails to perform in a satisfactory manner  
it should be replaced.
9.   One by one, turn the knobs to minimum and screw 
in the bypass screw (accessible when the knob is 
removed) until a small stable flame results. Turn the 
knob to maximum and then back to minimum to ensure 
that the correct minimum flame is maintained.
10.   Attach the LPG sticker to the cooker, near the gas 
supply inlet. Cover the Natural Gas label that is
factory fitted.
Flame size adjusted 
to maximum
Flame size adjusted 
to minimum
Bypass screw
Control knob shaft
Top hat nut assembly, 
fully screwed down
Turn top 
hat nut anti-
clockwise 
and remove
Configuration for 
Natural Gas
Configuration for LPG
A B
C D
E F
G H
34 LPG CONVERSION 35LPG CONVERSION










