User Manual

16 17INSTALLATION OF THE APPLIANCE WIRING REQUIREMENTS
Slot-in installation (continued)
The anti-tilt brackets are to be secured to the back
wall with appropriate fasteners.
Two stops are to be screwed to the plinth in
locations as shown (stops provided). The stops
locate into slots in the base of the appliance to
prevent the product from being pulled forward
when installed.
Measurements from the rear wall are to be adjusted
if there are tiles etc. that come between the
appliance and the wall.
Once services are connected, product can be lifted
onto the plinth and pushed back carefully, ensuring
the appliance engages into both brackets at the rear
and the front stops.
If the product requires removal for service, it must
be lifted at the front approximately 5mm to clear the
front stops prior to being pulled forward.
+
+
+
+
+
+
C
L
+
+
+
+
104 104
370 370
165 165
344
Location of holes
for front stops
Measurements are to be adjusted to account for the thickness of any skirting
board or tiles coming between the back of the appliance and the wall
344
Front stops
Front stops
WIRING REQUIREMENTS
The cooker MUST be installed in compliance with:
Wiring connections in AS/NZS 3000 Wiring Rules.
Local regulations, municipal building codes and
other statutory regulations.
For New Zealand Only:
The cooking range must be connected to the supply by
a supply cord fitted with the appropriately rated plug
that is compatible with the socket-outlet fitted to the
final sub-circuit in the fixed wiring that is intended to
supply this cooking range.
Supply cord size required:
WFE904SD/WFE915SD/WFE916DSD - 2.5mm
2
WFEP917DSD - 4.0mm
2
WFE946SD - 6.0mm
2
The Data plate gives information about rating and is
located behind the bottom of the oven door.
A functional switch MUST be provided near the
appliance in an accessible position (AS/NZS 3000
- Clause 4.7.1).
Wiring MUST be protected against mechanical failure
(AS/NZS 3000 - Clause 3.9).
Disconnection in the fixed wiring must occur in
accordance with the AS/NZS 3000 wiring rules.
The cooker MUST be properly earthed.
This range must be connected with cable of 75°C
rating minimum.
This product has passed the insulation resistance test
after manufacture. If the resistance reading is low at
installation, it is probably caused by moisture from
the atmosphere being absorbed by the elements after
the range has been produced. (Pass at 0.01 MΩ as per
AS/NZS 3000 - “Wiring Rules” clause 8.3.6.3).
Note: When connections are made to a multi-phase
230/240V supply, the bridge piece MUST be removed
from between the active connections.
Rated power input
MODEL TOTAL KW A1 KW A2 KW
WFE946 12.8 3.6 9.5
TIPS & INFORMATION
IMPORTANT
Before you cook in your new oven it is important that
the protective oils used in the manufacture of the
product be removed.
Make sure that the room is well ventilated (to allow
smoke to escape).
Run the grill on high for 30 minutes without grill dish.
Then run the oven on 180°C for 1 hour.
Connecting to services and commissioning
This appliance must be installed by an authorised
person, according to all codes and regulations of:
Electrical supply authorities.
Building regulations.
Local government and council authorities.
AS/NZS 5601.1 (Particular attention to clause 6.10.1
figure 6.3 and clause 6.10.1.11)
AS/NZS 3000 (particular attention to clause 4.7.1
and clause 3.9).
Securing points
Plastic clips
Plastic clip
Hard wiring detail
1. Remove terminal cover plate from rear panel
of appliance.
2. Fit wires through hole in cover plate and make
connections to terminals.
3. Engage wires into plastic clip. Secure plastic
clip with two long silver screws (supplied in
separate bag).
4. Replace cover plate onto rear panel.
INSTALLATION OF THE APPLIANCE (CONTINUED)