To avoid water damage or scalding due to relief valve operation:
Discharge line must be connected to relief valve outlet and
run to a safe place of disposal. Terminate the discharge line
in a manner that will prevent possibility of severe burns or
property damage should the relief valve discharge.
Discharge line must be as short as possible and the same
size as the valve discharge connection throughout its
entire length.
Discharge line must pitch downward from the valve
and terminate at least 6” above the oor drain, making
discharge clearly visible.
The discharge line shall terminate plain, not threaded, with
a material serviceable for temperatures of 375
o
F or greater.
Do not pipe discharge to any location where freezing could
occur.
No valve may be installed between the relief valve and
heater or in the discharge line. Do not plug or place any
obstruction in the discharge line.
Test the operation of the relief valve after lling and
pressurizing the system by lifting the lever. Make sure the
valve discharges freely. If the valve fails to operate correctly,
immediately replace with a new properly rated relief valve.
Test T&P valve at least once annually to ensure the waterway
is clear. If valve does not operate, turn the heater o and
call a plumber immediately.
Take care whenever operating relief valve to avoid scalding
injury or property damage.
FAILURE TO COMPLY WITH THE ABOVE GUIDELINES COULD
RESULT IN FAILURE OF RELIEF VALVE OPERATION, RESULTING
IN POSSIBILITY OF SUBSTANTIAL PROPERTY DAMAGE, SEVERE
PERSONAL INJURY, OR DEATH.
RE-INSPECTION OF T&P RELIEF VALVES: T&P valves should be
inspected AT LEAST ONCE EVERY THREE YEARS, and replaced if
necessary, by a licensed plumbing contractor or qualied service
technician to ensure that the product has not been aected by
corrosive water conditions and to ensure that the valve and
discharge line have not been altered or tampered with illegally.
Certain naturally occuring conditions may corrode the valve and
its components over time, rendering the valve inoperative. Such
conditions can only be detected if the valve and its components
are physically removed and inspected. Do not attempt to
conduct an inspection on your own. Contact your plumbing
contractor for a re-inspection to assure continued safety.
FAILURE TO RE-INSPECT THE T&P VALVE AS DIRECTED COULD
RESULT IN UNSAFE TEMPERATURE AND/OR PRESSURE BUILD-
UP WHICH CAN RESULT IN PROPERTY DAMAGE, SERIOUS
PERSONAL INJURY, OR DEATH.
Do not thread a cap or plug into the relief valve or relief valve
line under any circumstances! Explosion and property damage,
serious injury, or death may result.
F. Scalding
Approximate Time / Temperature Relationships in Scalds
120
o
F More than 5 minutes
125
o
F 1 1/2 to 2 minutes
130
o
F About 30 seconds
135
o
F About 10 seconds
140
o
F Less than 5 seconds
145
o
F Less than 3 seconds
150
o
F About 1 1/2 seconds
155
o
F About 1 second
Table 6 - Approximate Time / Temperature Relationships in Scalds
An ASSE 1017 or ASSE 1070 temperature limiting or mixing valve is
recommended in installations servicing disabled or elderly persons,
or children. Mixing valves do not eliminate the risk of scalding.
To avoid scalding:
Set the water heater set point temperature as low as possible.
Feel water before bathing or showering.
If thermostatic valves are required, use devices specically
designed for such purpose. Install these devices in accordance
with instructions provided by the manufacturer.
Failure to install a temperature limiting or mixing valve and follow
these instructions could result in property damage, severe personal
injury, or death due to scalds.
This water heater can
deliver scalding water.
Be careful whenever
using hot water to
avoid scalding injury.
Certain appliances
such as dishwashers
and automatic clothes
washers may require
increased water
temperatures. By setting
the thermostat on
this heater to obtain
the increased water
temperature required
by these appliances you
may create the potential
for scald injury.
To protect against injury,
install a mixing valve
in the water system.
This valve will reduce
point of use discharge
temperatures by mixing cold and hot water in branch supply lines.
Such valves are available from your local plumbing supplier.
Table 4 details the relationship of water temperature and time with
regard to scald injury and may be used as a guide in determining the
safest water temperature for your applications.
G. Filling the Heater
Make certain that the eld installed drain valve is completely
closed.
Open the shut-o valve in the cold water supply line.
Open the hot water faucets to allow air to vent from the heater
and piping.