Warranty
Table Of Contents
- Part 1 - General Safety Information
- Part 2 - Before You Start
- Part 3 - Prepare the Appliance Installation
- A. Locating the Appliance
- B. Leveling
- C. Clearances for Service Access
- D. Residential Garage and Closet Installations
- E. Exhaust Vent and Intake Pipe
- F. Carbon Monoxide Detectors
- G. Prevent Combustion Air Contamination
- H. Removing a Appliance from a Common Vent System
- I. Technical Specifications
- J. Wall-Mounting (Wall Mount Models Only)
- K. Flow Restrictor
- Part 4 - Water Piping
- Part 5 - Venting
- A. General
- B. Approved Materials for Exhaust Vent and Intake Pipe
- C. Additional Requirements for Installation in Canada
- D. Exhaust Vent and Intake Pipe Location
- E. Exhaust Vent and Intake Pipe Sizing
- F. Tightening Appliance Collar to Exhaust Vent and Intake Pipe
- G. Exhaust Vent and Intake Pipe Installation
- H. Applications
- Part 6 - Installing the Condensate Drain
- Part 7 - Connecting Electrical Service
- Part 8 - Gas Connections
- Part 9 - Controls
- Part 10 - Troubleshooting
- Part 11 - Start-Up
- Part 12 - Installation Checklist
- Part 13 - Maintenance
- Part 14 - Moving Adapters from Left to Right (Floor Models)
- Part 15 - Replacement Parts

42
whl-648 Rev. 000 Rel. 009 Date 1.4.19
Connector
Description HT Selv
No. of Location Pin Board Silk
CN9
65001WS-12
1 GROUND
HT (120V~) AC
2 L Power Supply Line
3 CP1 External CH Pump Power Supply (Live)
4 IT Ignitor Power Supply
5 L/(HT) Internal Pump Power Supply (Live)
6 GV Gas Valve Power Supply
7 -
8 N Power Supply (Neutral)
9-12 AC Power COM Line
CN6
LW6A4-03
1
CP2/3WAY 3 Way Valve
3
CN1
SMW250-03
1
RS-485
RS-485 +
SELV (5V) DC2 GND
3 RS-485 -
CN4
LWD1140-06
1
FAN
NOT USED -
2 GND
SELV (14V) DC
3 VDD
4 Fan power (start coil)
SELV (8 - 26.5V) AC
5 Fan power (end coil)
6 Fan speed feedback signal SELV (14V) DC
CN8
SMW250-04
1
MCU ISP
GND
SELV (5V) DC
2 ISP / Reset Port
3 ISP TOOL0 Data Port
4 VCC
CN11
LWD1140-16
1
HWL NOT USED
SELV (12V~) AC
8
2
LWL Low Water Level Sensor
10
3
HD Central Heating Demand (T/T) SELV (5V) DC
11
4
TH Display Control
SELV (14V) DC
12
5
APS Flue Air Pressure Switch
13
6
EL NOT USED
14
7
BL Burner High Limit
15
8
HL Condensate Air Pressure Switch
16
Table 21 - Boiler Wiring 1