Warranty
Table Of Contents
- Part 1 - General Safety Information
- Part 2 - Before You Start
- Part 3 - Prepare the Appliance Installation
- A. Locating the Appliance
- B. Leveling
- C. Clearances for Service Access
- D. Residential Garage and Closet Installations
- E. Exhaust Vent and Intake Pipe
- F. Carbon Monoxide Detectors
- G. Prevent Combustion Air Contamination
- H. Removing a Appliance from a Common Vent System
- I. Technical Specifications
- J. Wall-Mounting (Wall Mount Models Only)
- K. Flow Restrictor
- Part 4 - Water Piping
- Part 5 - Venting
- A. General
- B. Approved Materials for Exhaust Vent and Intake Pipe
- C. Additional Requirements for Installation in Canada
- D. Exhaust Vent and Intake Pipe Location
- E. Exhaust Vent and Intake Pipe Sizing
- F. Tightening Appliance Collar to Exhaust Vent and Intake Pipe
- G. Exhaust Vent and Intake Pipe Installation
- H. Applications
- Part 6 - Installing the Condensate Drain
- Part 7 - Connecting Electrical Service
- Part 8 - Gas Connections
- Part 9 - Controls
- Part 10 - Troubleshooting
- Part 11 - Start-Up
- Part 12 - Installation Checklist
- Part 13 - Maintenance
- Part 14 - Moving Adapters from Left to Right (Floor Models)
- Part 15 - Replacement Parts

17
whl-648 Rev. 000 Rel. 009 Date 1.4.19
Figure 5 - Components
Number Component Description Number Component Description Number Component Description
1 Air Vent 11 CH Return Adapter 21 Control Panel
2 Relief Valve Adapter 12 CH Pressure Gauge 22 Heat Exchanger
3 Air / Gas Mixing Pipe 13 DHW Outlet Adapter 23 Ignition Transformer
4 Gas Valve 14 Gas Inlet Adapter 24 Flame Detecting Sensor
5 Internal Storage Tank 15
DHW Inlet Adapter with Filter and
Flow Restrictor
25 BLDC Fan
6 Main PCB 16 Condensate Adapter 26 Air Pressure Switch
7 Manual ON/OFF Power Switch 17 Condensate Trap 27 Exhaust Vent Pipe
8
Internal Recirculation Pump (DHW) /
CH Internal Primary Pump
18 Condensate Air Pressure Switch 28 Exhaust Vent Adapter
9 CH Supply Adapter 19 Mixing Valve 29 Air Intake Adapter
10 CH Return Filter 20 Terminal Block
Table 12 - Component List
J. Wall-Mounting (Wall Mount Models Only)
The boiler may be installed on any suitable internal wall (suitable sound-proong may be required when installing onto a stud partition wall).
The boiler must be installed on a wall that can bear its weight (more than 110 lbs. when fully plumbed and full of water). Installing the boiler
on a wall which cannot support its weight could result in property damage, personal injury, or death.