Installation Manual
61
WHL-015 REV. 12.17.14
c. Do not open shutoff valve V1.
d. Allow water to flow through the appliance for 5 minutes.
e. Close shutoff valve V2.
8. Disconnect hoses from DHW lines. Properly dispose of used cleaning solution.
9. Remove the cold water inlet filter from the appliance and clean out any residues.
10. Reinsert the filter and ensure the filter cap is securely tightened.
11. Connect electrical power to the appliance.
Maintaining the Condensate System
The condensate trap assembly MUST BE PROPERLY INSTALLED according to these instructions when operating the appliance.
Operating the appliance without the condensate trap assembly will cause flue gases to leak and result in serious personal injury or
death.
When servicing is complete, make sure the condensate collector cap is replaced securely. Failure to do so will cause venting issues
that will result in serious injury or death.
1. Ensure the appliance is powered off and has had time to cool.
2. Remove the hose clamp attaching the condensate trap to the
condensate hose from the heat exchanger. Remove the clear plastic
hose from the hose barb. Remove the condensate hose clamp to
detach the condensate trap from the drain tube. Remove the
condensate trap from the appliance.
3. Remove the bottom cap from the condensate trap.
4. Flush trap with fresh water to remove debris from the trap.
NOTE: Ensure the float moves freely within the trap. If the float does
not move, DO NOT reinstall the trap.
5. When the condensate trap is sufficiently clean, reinstall the bottom
cap on the trap.
NOTE: Ensure all parts shown in Figure 47, Condensate Detail, are
installed with the condensate trap. If any parts are missing, DO NOT
reinstall the trap. Replace the entire assembly.
Do not install the condensate assembly if a component is lost or
missing. Replace the entire assembly. Failure to follow this warning
could result in property damage, serious personal injury, or death.
6. Fill the condensate trap with fresh water prior to reassembly on the
appliance.
7. Install the condensate trap on the condensate hose from the heat
exchanger. Use the hose clamp to secure the trap. Attach the clear
plastic hose onto the hose barb. Reinstall the condensate hose clamp
to detach the condensate trap from the drain tube.
Do not operate the appliance without the clear hose attached from the hose barb to the pressure switch. Failure to follow this warning
could result in property damage, serious personal injury, or death.
Figure 47 – Condensate Detail