Technical Literature
2
-/$%,)$%.4)&)#!4)/.#/$%3
%8&3")+
&3 " ) +
.OMINAL
#APACITY
(000) BTU
%LECTRICAL#ODE
+208/230-60-1
&3Air Conditioner
Design Series
0RODUCT
)DENTIlER
")Braze 20-25.5 SEER
$)-%.3)/.3
!)2#/.$)4)/.%2/54$//23%#4)/.
&3") + + +
H 37 41 45
W 31 1/4 31 1/4 31 1/4
D 31 1/4 31 1/4 31 1/4
0(93)#!,!.$%,%#42)#!,30%#)&)#!4)/.3/54$//25.)43
3%%25LTRA(IGH%FlCIENCY3INGLE0HASE
(1) Operating Voltage Range: 187v min. — 253v max.
(2) HACR Type Circuit Breakers may be used.
(3) Requires Reducers.
-ODEL.UMBER&3") + + +
Electrical Data
Volts-Cycles-Phase (1) 208/230-60-1 208/230-60-1 208/230-60-1
Total Amps 13.0 18.0 22.0
Delay Fuse Max. (2) 25 35 45
Min. Circuit Ampacity 16.6 22.9 27.1
Condenser Data
Coil
Area(ft
2
) 20.3 22.8 25.4
Rows-FPI 1 - 22 1 - 22 1 - 22
Tube Dia 3/8” O.D. 3/8” O.D. 3/8” O.D.
Fan Motor
Type Brushless DC Brushless DC Brushless DC
Amps 1.6 1.6 1.6
HP 0.5 0.5 0.5
Fan Blade
Dia-# Blades 24” - 2 24” - 2 24” - 2
SCFM 3200 3400 3600
Compressor Data RLA 11.4 16.4 20.4
Refrigerant suction line O.D.
(all length of liquid line are
3/8” O.D.)
0-24 ft. 3/4” 7/8” 7/8”
25-39 ft. 3/4” 7/8” 1 1/8” (3)
40-75 ft. 7/8” (3) 1 1/8” (3) 1 1/8” (3)
Refrigerant charge (R-410A) in ounces for outdoor
unit, indoor unit and 15’ lineset.
160 168 188
Weight Net 170 175 180
Approximate (lbs.) Ship 180 185 190
./4%2EFRIGERANT4UBING,IMITATIONSThe compressor manufacturer
imposes a maximum equivalent line set length of 100ft. Furthermore,
vertical elevation shall not exceed 50 ft.