User Manual
Page 63
Section 9: Z-Wave functionality (RTS-Z & RTS-PZ)
9.1 Alarm/Notification functionality
When Door is locked or unlocked by the controller or user, the device notifies to the
controller by using Notification.
9.2 Compatibility
This product can be included and operated in any Z-Wave network with other Z-Wave
certified devices from other manufacturers and/or other applications. All non-battery
operated nodes within the network will act as repeaters regardless of vendor to increase
reliability of the network.
9.3 Association Group
Grouping identifier is 1 and maximum number of devices that can be added to the group
is 5.
When the battery of the device is lower than a specific threshold the door will still lock or
unlock or the device can be reset. It will notify the controller that the operation was
completed and of the low battery condition.
The lifeline group contains Battery, DoorLock, Notification and Device Reset Locally
messages.
9.4 Controller Compatibility
The device is Z-Wave security enabled and a Z-Wave Security enabled controller is
required to fully utilize the device.
Section 10: External Applications
There are 3 separate external items that can be wired up to the Locks
1. Auxiliary 6 Volt Power Supply: red and black wires
2. Normally Open Items: blue and white wires
3. RS485 Switches: yellow, brown and black wires
10.1 Auxiliary Power Connection
Red and black wires with inline connector
This is the optional DC power connection