Select the type and click Next. The screen below will appear.
Lock ID: A number between 1 and 9999. This must be unique for each lock. This value will auto-
increment with each lock you create. Remember to manually administer this Lock ID at the lock itself as
this value is not read by the lock but is very important to correctly Importing/Exporting via USB as well
as in correctly deciphering the audit trail using the Events tab.
Lock Name: A descriptive name for the lock. RoomXXX is suggested by default but can be any name you
choose.
IP Address: Network address. This is required for PoE locks. If you are using a PoE lock but do not have
a network address, leaving this field blank will populate it with the value 255.255.255.255. This field
cannot be accessed if you selected USB or Z-Wave as the lock type.
Fingerprint Sensitivity: This is a number between 1 and 9 which controls the matching of the scanned
fingerprint with the stored fingerprint. 1 is the strictest setting. A setting of 1 requires an almost
perfect finger placement. 9 is the least strict and is the recommended setting.
1:1 : When this is chosen, all users enrolled at this lock must enter their User ID, then verify their
enrolled Fingerprint or PIN Code to successfully unlock the door.
1:N : When this is chosen, all users enrolled at this lock only need to match their enrolled Fingerprint OR
PIN Code to unlock the door.
Both (1&N): All enrolled users can use either the 1:1 or 1:N method to unlock the door.
Choose either 1:1, 1:N, or Both.