Full Product Manual
English | 17
FIG. 11
OPERATION
DATA CENTER
See Figure 11.
Push the mode button to cycle through the data display
modes.
Voltage: Displays current voltage output.
Frequency (Hz): Displays power output frequency in
Hertz.
Lifetime Hours: Displays the lifetime run hours.
Fuel Level: Indicates how much gasoline remains in
the fuel tank.
Run Time/Maintenance: Displays current run time.
Resets to zero when shut down. Maintenance reminder
displayed when required.
Maintenance Codes:
P25 - Change engine oil
P50 - Clean air lter, Change engine oil
P100 - Change engine oil, clean air lter, replace
fuel lter
BREAK-IN PERIOD
For proper break-in, do not exceed 50% of the rated
running watts during the rst ve hours of operation.
Use supplied oil until rst recommend oil change. Do
not use full synthetic oil during break in period. Full
synthetic oil may prevent proper breaking and seating
of the piston rings.
Vary the load occasionally to allow stator windings to
heat and cool and help seat the piston rings.
BEFORE STARTING THE GENERATOR
Verify that:
lThe generator is placed in a safe, appropriate location.
lThe generator is on a dry, at, and level surface.
lOil and fuel levels are within safe operating range.
lAll loads are disconnected from the control panel
receptacles.
lThe ECO mode switch is in the OFF position.
DANGER
Fire and explosion hazard. DO
NOT move or tip the generator during operation.
STARTING THE GENERATOR
See Figures 12 - 14.
lPlace the generator in a safe, appropriate location.
lUnplug all loads.
lEnsure the ECO mode switch is in the OFF position.
lCheck oil and fuel levels. If needed, add fuel or oil as
described earlier.
lTurn the vent knob on the fuel cap to the ON position.
FIG. 12
A - Vent Knob
B - On
C - Off
A
C
B
F
A - Voltage
B - Power Output
C - Lifetime Hours
D - Fuel Level
E - Run Time/Maintenance Reminder
F - Mode Button
A
B
D
E
C