Full Product Manual
English | 15
OPERATION
FIG. 7
A - Engine Service Cover
B - Locked Positoin
C - Unlocked Positoin
A
C
B
FIG. 8
A - Oil Dipstick
B - Safe Operating Range
A
B
lTurn the generator off and allow the engine to cool for at
least ve minutes.
lPlace the generator on a level surface in a well-
ventilated area.
lTurn the lock knob to the unlocked position.
lRemove the engine service cover.
lClean the area around the oil dipstick.
For initial oil ll:
lSlowly unscrew and remove the oil dipstick.
lUsing the funnel, slowly pour the supplied engine oil
into the oil ll hole. Stop frequently to make sure you do
not overll.
NOTE: Your generator was functionally tested in the
factory and may contain minimum residual oil. Additional
oil is required to operate the unit. Do not overll.
lReplace and tighten the oil dipstick.
lInstall the engine service cover and turn the lock knob
to the locked position to secure.
To check oil level:
lSlowly unscrew and remove the oil dipstick.
lClean the dipstick and re-seat it inside the oil ll hole.
Do not thread the dipstick.
lRemove the dipstick and verify that the oil level is within
safe operating range.
lIf the oil level is low, add recommended engine oil
incrementally and recheck until the level is within the
safe operating range.
lReplace the oil dipstick and hand-tighten.
lInstall the engine service cover and turn the lock knob
to the locked position to secure.
GASOLINE REQUIREMENTS
NOTICE
Do not use E15 or E85 fuel
in this product. Engine or equipment damage
caused by stale fuel or the use of unapproved fuels
(such as E15 or E85 ethanol blends) is not covered
by warranty. Only use unleaded gasoline containing
up to 10% ethanol.
lALWAYS use CLEAN, FRESH, unleaded gasoline (87–
93 octane) in this unit. NEVER use OLD, STALE, or
CONTAMINATED gasoline.
lUp to 10% ethanol (gasohol) is
acceptable (where available; non-
ethanol fuel is recommended).
lDO NOT use E85 or E15.
lDO NOT use a gas oil mix.
lDO NOT modify the engine to run on alternate fuels.
E85 E15