39 DC braking level 000~020% 005
40
Carrier frequency 004~016 010 4~16K
41
Auto Restart for power-loss
000: Enable
001: Disable
000
42
Auto-restart times
000~005
000
43 Motor rated current *4
44 Motor rated voltage *4
45 Motor rated frequency *4
46 Motor rated power *4
47 Motor rated speed *4
48 Torque Boost Gain (Vector) 001~450
49
Slip Compensation Gain
(Vector)
001~450
50
Low frequency voltage
compensation
000~40
51
Advanced parameter
function display
000: don’t display
001: display
000 *1
52 Factory default
010: Reset to factory default (50Hz)
020: Reset to factory default (60Hz)
000
53 Software version CPU Version *3 *4
54 Latest 3 fault records *3 *4
Advanced function parameter list
(Enable access to these parameters by setting F51=001)
C Function Description Range/ Code
Factory
default
Remarks
00
Reverse run instruction
000: Reverse enable
001: Reverse disable
000
01
Acceleration stall-
prevention
000: Acceleration stall prevention enable
001: Acceleration stall prevention disable
000
02
Acceleration stall-
prevention level (%)
050 - 200 200
03
Deceleration stall-
prevention
000: Deceleration stall prevention enable
001: Deceleration stall prevention disable
000
04
Deceleration stall-
prevention level (%)
050 - 200
200
05 Run stall-prevention
000: Run stall prevention available
001: Run stall prevention unavailable
000
06
Run stall-prevention
level (%)
050 - 200 200
07
Stall prevention time
during run
000: according to decel time set in F02
001: according to decel time set in C08
000
08
Stall prevention
deceleration time set
00.1 – 999 Sec
03.0
09 Direct start on power up
000: Direct start available
001: Direct start disabled
001
10 Reset mode
000: RUN instruction is OFF, Reset
command is available.
001: Whether RUN instruction is OFF or
ON, Reset command is available.
000