Instruction manual
15
Chapter 2 Programming instructions & Parameter list
2.1 Operation Instruction of the keypad
*1: Display flashes with set frequency in stop mode, but it is solid in run mode.
*2: The frequency can be set during both stop and run modes.
Remote/Local change function
• Local mode
Run command via RUN/STOP key on the keypad
Frequency command
When C41=000: only UP/DOWN key on the keypad can control and F05 setting has
no effect.
When C41=001: only VR on the keypad can control and F05 setting has no effect.
• Remote mode
Run command from Run parameter (F04) control setting
Frequency command from Frequency parameter (F05) control setting
•Remote/Local change mode
on keypad is achieved by simultaneously pressing /RESET and
VALUE