Use and Care Manual

LP-436 Rev. 5.2.18
7
Figure 2 - Water Heater Dimensions - NOTE: All Dimensions Are Approximate
Model
Storage Capacity Gallons
(Liters)
Fuel
Type
Input
(BTU)
Recovery 90
o
F / 50
o
C
Gallons (Liters) Per Hour
Shipping Weight Lbs.
(Est.)
CG125N73 72 (272)
NG
125,000 135 (511)
429CG150N73 70 (265) 150,000 162 (613)
CG199N73(X) 68 (257) 199,900 215 (814)
CG250N65 60 (227) 250,000 269 (1018)
465
CG300N65 55 (208) 300,000 323 (1223)
Model Dimensions in Inches
Model A B C D E1 E2 F H I J K
CG125N73
15 3/4
52 1/2
64 1/8 5 7/8 25 1/4 58 1/4
69 1/4 5
26 1/2 40.3
o
51.2
o
CG150N73
70 7/8
6
CG199N73(X)
CG250N65
52 1/8
7
CG300N65 71 5/8 8
Table 2 - Specications and Dimensions - NOTE: All Water Heaters Shipped to Operate on Natural Gas - A sux of “X” Denotes Model Set for Low
NOx Operation
Failure of the water heater or components due to incorrect
operating conditions IS NOT covered by product warranty.
B. Minimum Clearances
The minimum clearances from combustible materials for this water
heater are: 6” (15.2 cm) from the sides and rear, 24” (61 cm) from the
front, and 18” (45.7 cm) from the top.
NOTE: If you do not provide the minimum clearances shown in
Figure 2 it might not be possible to service the heater without
removing it from the space.
Figure 1 - Minimum Service Clearances