MANUALLY STARTING A GENERATOR
NOTE: This procedure can also be used on an 
 electric start generator.
1.  Check oil levels (see Adding Engine Oil page 24)
2.  Make sure the circuit breakers are properly set (see 
Figure 13 below).
 240/120VMain Circuit Breaker Operating Position
 240/120V Main Circuit Breaker Tripped Position
 120V Circuit Breaker Operating Position
 120V Circuit Breaker Tripped Position
2.  Move the fuel shut o valve to the ON position (see 
Figure 14 below).
Figure 14 - Fuel Shut O - ON
3.  Move the choke lever to the ON position 
(see Figure 15 below).
Figure 15 - Choke - ON
4.  Push the engine control switch into the RUN 
position (see Figure 16 below).
5.  Firmly grasp and pull the recoil handle slowly until 
you feel increased resistance. At this point, apply 
a rapid pull while pulling up and slightly away from 
the generator (see Figure20).
6.  As the engine starts and stabilizes, gradually move 
the choke lever back to the OFF position. (Figure 18)
Figure 18 - Choke - OFF
OPERATION 
Figure 13 - Breakers
Figure 16 - Engine Control Switch - RUN
Figure 17 - Engine Recoil Handle - PULL
1
2
3
4