Replacement Part List

Westinghouse Portable Power | 15
20-Amp Circuit Breakers: Each circuit breaker
limits the current that can be delivered through
the 120-volt duplex outlets to 20amps.
Battery Charge Port: Used in conjunction with
the ATS when the generator is in standby mode to
charge the battery (battery charger not included).
Battery Indicator Light: When light is illuminated,
the battery is connected and providing power to
the electronics.
ATS Outlet: Connects the Automatic Switch to
the control panel (ATS not included).
Ground Terminal: The ground terminal is used to
ground the generator.
One Push Start Button (for One Push Start Units):
Push once to automatically start the engine.
Green light shows when unit is on.
Push again to stop the engine.
Battery Disconnect: Push anytime to stop the
engine. When pressed it prevents the unit from
drawing power from the battery. Twist to unlock.
Hour Meter: Displays how many hours the
generator has been run when under load.
Main Circuit Breaker: The main circuit breaker
controls total output of all outlets to protect the
generator.
120/240-Volt, 30-Amp Twist Lock Outlet
(NEMA L14-30R): Outlet can supply either
120V or 240V output.
120-Volt, 20-Amp Duplex GFCI Outlets
(NEMA 5-20R): Each outlet is capable of carrying
a maximum of 20 amps on a single receptacle or a
combination of both receptacles.
OPERATION
CONTROL PANEL FEATURES
1
8
9
10
11
2
3
4
5
6
7
3 4 5 6 721
10 1198
Figure 8 - Electric Start Control Panel Features