Technical Literature
7
NOTE:Ifelectricheatisinstalled,andtheovercurrentratingexceeds60A,internalcircuitbreakers
mustbeinstalledinadditiontobranchcircuitprotectionatthedistributionpanel.
ACCESSORIES
NA=NotApproved
()=Numberofinternalcircuitbreakerkitsrequired.
X=Branchcircuitprotectiononly
NOTE:Blowerperformanceheatingvaluesbasedon10kwheaterkitforX24k,andX36k.15kwvaluesusedforX48k.
Heater Application Matrix
Model
Number
Q5RF-
H3HK-
005H-01B
917166B
H3HK-
008H-01B
917167B
H3HK-
010H-01B
917168B
H3HK-
015H-01B
917169B
H3HK-
020H-01B
917170B
H3HK-
015H-21B
917172B
H3HK-
020H-21B
917173B
X24KA X(0) X(0) X(2) NA NA NA NA
X36KA X(0) X(2) X(2) X(2) NA X(0) NA
X48KA X(2) X(2) X(2) X(2) X(3) X(0) X(1)
X60KA X(2) X(2) X(2) X(2) X(3) X(0) X(1)
Description
Part Number
4-PoleSingleCircuitAdaptor 913350
6-PoleSingleCircuitAdaptor 913556
CircuitBreakerSinglePhase(2-pole) 913554
Extremehighwindkit-groundmount 920908
DuctCollar-12" 917701
DuctCollar-14"
917702
MODEL IDENTIFICATION CODE
H 3 HK 008 - H 0 1
Heater
Heater Kit
3-Pkgd. Units
Electric
Heater KW
No. of Breakers
Electric Code
H=240-1-60
Stages