Technical Literature
3
(1)OperatingVoltageRange:187vmin.-253vmax.
(2)HACRTypeCircuitBreakersmaybeused.
(3)Requires7/8”to3/4”reducerfromlinetounit.
(4)Requires7/8”to1-1/8”reducerfromlinetounit.
Notes:
Additionalchargeforlinesetsabove15feet.
Valuesbasedonsuctionlineasfollowswith3/8”liquidline.
a)3/4”=0.6oz.peradditionalfoot.
b)7/8”=0.7oz.peradditionalfoot.
c)11/8”=0.8oz.peradditionalfoot.
PHYSICAL AND ELECTRICAL SPECIFICATIONS / OUTDOOR UNITS
14 SEER — High Efficiency — Single Phase
ACCESSORIES - Condensing Unit
Start Assist Kit - 912933
Providesadditionalstartingtorqueforthecompressor
motorwhenoperatingwithlowlinevoltageorhighoper-
atingtemperatures.
Model Number FS4BE 018KA 024KA 030KA 036KA 042KA 048KA 060KA
Electrical
Data
Volts-Cycles-Phase(1) 208/230-60-1
TotalAmps 9.9 14.4 15.0 15.1 19.4 21.3 29.0
DelayFuseMax.(2) 20 30 30 30 40 45 60
Min.CircuitAmpacity 12.1 17.7 18.5 18.6 23.9 26.3 35.6
Component
Data
Coil
Area 10.0 11.7 15.2 20.3 22.8 22.8 25.4
Rows-FPI 1-23 1-23 1-18 1-18 1-18 1-18 1-23
TubeDia MC
FanMotor
Type PSC BLDC
Amps 0.9 0.9 0.9 1.0 1.5 1.5 2.6
HP 0.13 0.13 0.13 0.20 0.25 0.25 0.33
Compressor
Data
RLA 9.0 13.4 14.1 14.1 17.9 19.8 26.4
LRA 48.0 58.3 73.0 77.0 112.0 109.0 134.0
RefrigerantsuctionlineO.D.
NOTE:Liquidlineis3/8”O.D.for
entirelength.
0-24ft. 3/4” 3/4” 3/4” 3/4” 7/8” 7/8” 7/8”
25-39ft. 3/4” 3/4” 3/4” 7/8”(3) 7/8” 7/8” 1-1/8”(4)
40-75ft. 3/4” 3/4” 3/4” 7/8”(3) 7/8” 7/8” 1-1/8”(4)
Refrigerantcharge
inouncesforoutdoorunit&15’lineset
39.0 45.0 51.0 62.0 75.0 101.0 81.0
ApproximateWeight(lbs.)
Net 107 127 132 146 175 177 187
Ship 113 134 140 155 184 186 196
SoundRatingdb 73 73 72 75 75 75 75