Use and Care Manual

31
MAINTENANCE
1
2
Figure 35
1 - Red Positive (+)
Battery Cable
2 - Black Negative (-)
Battery Cable
NOTICE
Dispose of the used battery properly according to
the guidelines established by your local or state
government.
6. Install the new battery into the generator frame.
7.
Connect the red positive (+) battery cable to the
battery first.
8. Connect the black negative (-) battery cable to the
battery second.
9. Install the battery hold-down plate using the nuts
removed in step 2.
10. Install the spark plug wire onto spark plug.
The battery is the same as a wheelchair battery.
Type Sealed lead-acid
Model LA-12V20-NB
Volts 12
Amp 21
Dimensions (L x H x W) 7.13 x 3 x 6.63 in.
(18.1 x 7.6 x 16.8 cm)
CLEANING THE ENGINE OIL
COOLER
1. Remove the screws for the oil cooler (see Figure
36).
2
1
1
3
Figure 36 – Engine Oil Cooler
1 - Oil Cooler
Screws
2 - Oil Cooler Guard
3 - Oil Cooler
2. Remove the oil cooler guard and the oil cooler.
3. Inspect the oil fins for dirt and debris. Clean the fins
using compressed air not to exceed 30 psi (207
kPa) (see Figure 37).
Figure 37 – Oil Cooler Fins
4. Install the oil cooler and guard using the screws.