Specifications

inStallation Set-uP
H
Dimension ‘H’ obtained
from table to the left.
Table 3: Minimum ‘H’ for Figure 40.
Roof Pitch Minimum Height (H)
Feet Meters
Flat to 7/12 1 0.3
Over 7/12 to 8/12 1.5 0.46
Over 8/12 to 9/12 2 0.61
Over 9/12 to 10/12 2.5 0.76
Over 10/12 to 11/12 3.25 0.99
Over 11/12 to 12/12 4 1.22
Over 12/12 to 14/12 5 1.52
Over 14/12 to 16/12 6 1.83
Over 16/12 to 18/12 7 2.13
Over 18/12 to 20/12 7.5 2.29
Over 20/12 to 21/12 8 2.44
Figure 40: Height of Vertical Termination;
Reference Table 3.
DooR RemovaL anD instaLLation:
1) The replace door is hung on two (2) hooks on the top of the
rebox. The two (2) door latches at the bottom of the rebox
hook over the tabs on the bottom of the door frame.
2) Lower the door latch tool underneath the door frame. Catch the
lower door latch with the door latch tool (see Figure 41) and
pull it out slightly, then down. Once the lower door latch clears
the tab on the bottom of the door frame, release it inwards and
then remove the door latch tool. Refer to Figures 43 & 44.
3) Pull the Door Frame at the bottom forward about 2” (5cm),
then lift the Door Frame upwards to clear the
Figure 41: Door Latch /Air Adjustment Tool.
Figure 43: Door Latch Tool in Place. Figure 42: Door Latch Locations.
28