Specifications

Planning your inStallation
Figure 19. Option 3 - Fireplace Facing Less than 1” (25.4mm) Thick
With Optional Fronts Installed.
instaLLation oF FiRepLace Facing continueD:
When installing the DV62 with the optional door and you plan to install rock or tile facing that is thinner than
1” (combined with the non-combustible board supplied), you do not need to install any optional trim. The
minimum air gap between the optional door set and the wall must be maintained as shown. Failure to maintain
this air gap will result in elevated operating conditions.
Figure 18. Option 2 - Fireplace Facing More Than 1” (25.4mm) Thick With
Optional Fronts Installed.
When installing the DV62 with the optional door and you plan to install rock or tile facing that is thicker than 1”
(combined with the non-combustible board supplied), you must install the wall trim kit that is supplied with the
unit. The optional wall trim is fastened to the non-combustible wall board that comes with the unit and the rock
or tile facing covers over the trim ange as with any typical drywall ange. The minimum air gap shown on the
drawing must be maintained between the optional door set and the wall as well as between the facing and the
door set as shown.