User`s guide
1-2
Introduction
Model Numbers Covered
This User’s Guide discusses several different models from our TSM Series, RSM Series
and RSM-8R Series product line. Throughout this User's Guide, all of these units are
referred to as the "TSM/RSM." Note however that these units differ as described below:
Model No.
Input Voltage
Serial Ports
Internal
Modem
TSMSeries:
TSM-8 100 to 240 VAC 8 ea., RJ45 Yes
TSM-8DC -48 VDC 8 ea., RJ45 Yes
TSM-8-NMI 100 to 240 VAC 8 ea., RJ45 No
TSM-8DC-NMI -48 VDC 8 ea., RJ45 No
TSM-24 100 to 240 VAC 24 ea., RJ45 Yes
TSM-24DC -48 VDC 24 ea., RJ45 Yes
TSM-24-NMI 100 to 240 VAC 24 ea., RJ45 No
TSM-24DC-NMI -48 VDC 24 ea., RJ45 No
TSM-24-DPS 2 ea., 100 to 240 VAC 24 ea., RJ45 Yes
TSM-40 100 to 240 VAC 40 ea., RJ45 Yes
TSM-40DC -48 VDC 40 ea., RJ45 Yes
TSM-40-NMI 100 to 240 VAC 40 ea., RJ45 No
TSM-40DC-NMI -48 VDC 40 ea., RJ45 No
TSM-40-DPS 2 ea., 100 to 240 VAC 40 ea., RJ45 Yes
RSMSeries:
RSM-8 100 to 240 VAC 8 ea., DB9 Yes
RSM-16 100 to 240 VAC 16 ea., DB9 Yes
RSM-16DC -48 VDC 16 ea., DB9 Yes
RSM-32 100 to 240 VAC 32 ea., DB9 Yes
RSM-32DC -48 VDC 32 ea., DB9 Yes
Model No.
Input
Voltage
Serial
Ports
Outlets
Input
Feed
Max.
Load
RSM-8RSeries(AllModelsListedIncludeInternalModem):
RSM-8R4-1 100 to 120 VAC 8 ea., RJ45 4 ea., NEMA 5-15R 15 Amp 12 Amps*
RSM-8R4-2 100 to 240 VAC 8 ea., RJ45 4 ea., IEC C13 15 Amp 12 Amps*
RSM-8R4-1-DCM 100 to 120 VAC 8 ea., RJ45 4 ea., NEMA 5-15R 15 Amp 12 Amps*
RSM-8R4-2-DCM 100 to 240 VAC 8 ea., RJ45 4 ea., IEC C13 15 Amp 12 Amps*
RSM-8R8-1** 2 ea., 100 to 132 VAC** 8 ea., RJ45 8 ea., NEMA 5-15R 20 Amp 16 Amps*
RSM-8R8-2*** 2 ea., 200 to 240 VAC*** 8 ea., RJ45 8 ea., IEC C13 20 Amp 16 Amps*
* In accordance with UL requirements for branch circuits, this value has been
de-rated to 80%.
** The input voltage for RSM-8R8-1 units must be between 100 and 132 VAC. Other
voltages will cause damage to the unit.
*** The input voltage for RSM-8R8-2 units must be between 200 and 240 VAC. Other
voltages will cause damage to the unit.