User`s guide

3-7
Getting Started
d) ViaTelnet: Make certain that Telnet access is enabled as described in the RPC
User’s Guide. Start your Telnet client, and enter the RPC's default IP address
(192.168.168.168).
e) ViaModem: Make certain that the RPC Console Port has been configured
for Modem Mode as described in the RPC User's Guide, then use your
communications program to dial the number for the external Modem
connected to the Console Port.
2. Username/PasswordPrompt: A message will be displayed, which prompts you
to enter your username and password. The default username is "super" (all lower
case, no quotes), and the default password is also "super". If a valid username and
password are entered, the RPC will display either the Circuit Control Screen (Web
Browser Interface) or the Circuit Status Screen (SSH, Telnet, or Modem).
3. TestSwitchingFunctions: You may wish to perform the following tests in order
to make certain that the RPC is responding to commands. When switching and
reboot commands are executed, the Status LED(s) will also turn On or Off to
indicate the current status of the circuit(s).
a) RebootCircuit:
i. WebBrowserInterface: Click on the "Circuit Control" link on the left hand
side of the screen to display the Circuit Control Menu. From the Circuit
Control Menu, click the down arrow in the row for Circuit 1 to display the
dropdown menu, then select "Reboot" from the drop down menu and click
on the "Execute Actions" button.
ii. TextInterface: Type /BOOT 1 and press [Enter].
b) SwitchCircuitOff:
i. WebBrowserInterface: From the Circuit Control Menu, click the down
arrow in the "Action" column for Circuit 1 to display the drop down menu,
then select "Off" from the drop down menu and click on the "Execute
Actions" button.
ii. TextInterface: Type /OFF 1 and press [Enter].
c) SwitchCircuitOn:
i. WebBrowserInterface: From the Circuit Control Menu, click the down
arrow in the "Action" column for Circuit 1 to display the drop down menu,
then select "On" from the drop down menu and click on the "Execute
Actions" button.
ii. TextInterface: Type /ON A1 and press [Enter].
This completes the Quick Start Guide for the RPC. Prior to placing the unit into
operation, it is recommended to refer to the remainder of this User’s Guide for important
information regarding advanced configuration capabilities and more detailed operation
instructions. If you have further questions regarding the RPC unit, please contact WTI
Customer Support as described in Appendix C.