User`s manual

Western Reserve Controls WRC-CANR-DF-DN Users Manual
PUB 14.2 Series 4
8
Table 4-4 Diagnostic Status LEDs (labeled DNG)
LED State Module Status Meaning
OFF Normal Normal operation.
Green Fiber Link OK Serial link to fiber network operating.
Red Time-out
Unit has not received a serial message
(status or can) from the fiber link.
Flashing Red Communications error
Internal FIFO stack has overflowed on the
fiber link interface.
The Green TXF and RXF LEDs are illuminated when data is actively transmitted out to the fiber
link.
4.3. DIP Switch Settings
The WRC-CANR-DF has an 8-pole DIP switch.
Switch positions 1-4 are used to set the baud rate of the CANR on which it is located
(the local unit).
Switch positions 5-8 are used to set the baud rate on the CANR at the other end of
the fiber cable (the Remote Device).
The baud rates can be set independently, or one side can take its baud rate from the other side
(in the Remotesetting).
The Autobaud detects from DeviceNet bauds.
For CANopen speeds, select the fix baudrate setting.
When both the CANR units are set to all open switch positions (remote-remote) it scans through
DeviceNet baudrates.