User manual
WRM15
dualB
USER MANUAL
Rev. 1.1
20/06/2016
This document is the property of WESTERN CO. Ltd. - All rights are reserved - Reproduction and use of information contained Within this document is forbidden without the written consent of WESTERN CO. Ltd.
2
0
Electrical features
Nominal battery voltage 12V
Nominal battery voltage 24V
Min
Typ
Max
Min
Typ
Max
Battery voltage
Vbatt
10V
17V
20V
34V
Open circuit module voltage
Vpan
20V
-
100V
40V
-
100V
Module voltage
ipan
-
-
15A
-
-
15A
Maximum module power
Pmax
-
-
250W
-
-
500W
Load output voltage
Vload
-
Battery
voltage
-
-
Battery
voltage
-
Load voltage
Iload
-
-
15A
-
-
15A
Charging voltage at 25 ° C SEAL program (default)
Vch
14.4V
28.8V
Charging voltage at 25 ° C program FLOOD
Vch
14.8V
29.6V
Charging voltage at 25 ° C program LEO
Vch
14.4V
28.8V
Charging voltage for Li
program (*)
Vch
14.0V
-
14.7V
28.0V
-
29.4V
Compensation of Vch function of battery temperature (Tbatt)
Vtadj
-
-
24mV / ° C
-
-
-
48mV / ° C
-
Low battery voltage (adjustable)
Vlb
10.8V
11.4V
(default)
12.2V
21.6V
22.8V
(default)
24.4V
Low battery
output voltage
Vout_lb
12.4V
13.8V
13.8V
24.8V
27.6V
27.6V
Detection voltage during the day (adjustable)
Vday
2.4V
4.8V
(default)
9.6V
4.8V
9.6V
(default)
19.2V
Detection voltage: VNIGHT Vday =
-
0.8V
Vnight
1.6V
-
8.8V
4.0V
-
18.4V
Voltage for Float
phase (Adjustable)
VFlt at 25 ° C
13.2V
13.4V
(default)
14.4V
26.4V
26.8V
(default)
28.8V
Phase Absorption Time (Adjustable)
TAbsorption
1.0 h
3.0 h
(default)
4.0 h
1.0 h
3.0 h
(default)
4.0 h
Self
-
consumption
isleep
12.7mA
(Vbat
14,0V)
17,7mA
(Vbat
28,0V)
Working temperature:
Tamb
-
10°C
50 ° C
-
10°C
50 ° C
Dissipated power
Pdiss
20 W
29 W
Section to terminals
1mm
2
10mm
2
1mm
2
10mm
2
Protection degree
IP20
IP20
Weight
-
515 g
-
-
515 g
-
Warranty
Western CO. Srl guarantees the good quality and good design of its own Products obliging itself, during the warranty period of 5
(five) years, to repair or replace at its sole discretion, for free, those defective parts owing to poor quality of material or defect in
workmanship.
The defective product must be returned to Western Co. Srl or to the company delegated by Western Co to make product support, at
customer’s expenses, together with a copy of the invoice both for repairing and warranty replacement. The costs of re-installation
of the equipment will be borne by the customer.
Western CO. Srl will bear the transport expenses of the repaired or replaced product. The warranty does not cover Products that,
according to our discretion, are defective due to natural wear, showing damages caused by incompetence or negligence of the
customer, imperfect installation, by tampering or other interventions different by the instructions supplied by us. The warranty is
not valid also in case of damages coming from:
- transport and/or incorrect storage of the product.
- force majeure or catastrophic events (frost to temperatures below -20 ° C, fire, flood, lightning, vandalism, and so on).
All of the abovementioned guarantees are the sole and exclusive agreement which supersedes any proposal or agreement, oral or
written, and any other communication made between the manufacturer and the purchaser in respect of the above. For any dispute
the jurisdiction is Ascoli Piceno.
Waste disposal
Western CO. as manufacturer of the electrical device herein described and in accordance with DL 07/25/2005 n 151, informs the
consumer that this product, once abandoned, must be delivered to an authorized collection centre or, in case of purchase of an
equivalent equipment, it can be returned free of charge to the distributor of the new equipment. The penalties will be applied by
individual Municipalities.
WESTERN CO. Srl
Via Pasubio 1
63074 San Benedetto del Tronto (AP)
Phone: 0735 751248 Fax 0735 751254
e-mail: info@western.it
web:
www.western.it