User guide
9
6641-2211
Interface specifications
Power and fault relay port PWR
Rated voltage 24 to 110 VDC
Operating voltage 24 to 110 VDC ±40%
Rated current 30 mA @ 110 VDC
90 mA @ 24 VDC
Rated frequency DC
Inrush current, I
2
t Max 0.02 A
2
s @ 24 – 110 VDC
Polarity Reverse polarity protected
Redundant power input No
Isolation to Connections X1 – X8 and to ground, 1500 VAC.
Fault relay belongs to the same isolation group as the power
supply lines (fault relay signals are also contained within
PWR).
Connection 4 pin male M12 connector with A-code
Connector size M12, recommended cable area 0.5 mm
2
recommended
(minimum 0.25 mm
2
), cable dimensions depend on choice of
M12 connector
Shielded cable Not required, twisted pair is recommended
Fault relay resistance < 10 Ω
Operating voltage Up to 110 VDC
M12 A-Coded
Power
Connector
Position Direction Description
1 U+ Positive supply voltage
2 Out Alarm relay (status) +
3 0 V Negative supply voltage
4 Out Alarm relay (status) –
Housing Shield Chassis of product (ground)