Specifications
V4.5
www.westermo.com
U/R/T200 series
- 47 -
13.4 Environmental Specification
Indoor use or corresponding environment
Altitude up to 2000M
Operating temperature (-40 .. +65’C) (55deg on F8)
Humidity 5-95’C
Enclosure IP40
13.4.1 Climatic
Cold IEC 68-2-1 Ad (-40 ‘C operational 16 Hours)
Storage IEC 68-2-1 Ad (-40 ’C 16 Hours)
Dry Heat IEC 68-2-2 Bd (+70 ’C operational 16 Hours)
Humidity IEC 68-2-30 Db (25 ‘C .. 55 ‘C 95% 6 Cycles 24 Hours)
13.4.2 Mechanical
Oscillation IEC 255-21-1 Class 1
Shock IEC 255-21-2 Class 1
Enclosures IEC 529, IP 40
13.4.3 Electromagnetic Compatibility (EMC)
Industrial Immunity EN 61000-6-2
Industrial Emission EN 50081-2
Home / Office Emission EN 50081-1
13.4.4 Radiated Immunity
ESD EN 61000-4-2 (4/8 kV)
Magnetic Field EN 61000-4-8 (300A/m)
RF Field Disturbance EN 61000-4-3
10 V/m 80% AM
80 .. 1000MHz
13.4.5 Conducted Immunity
Fast Transients EN 61000-4-4
AC/DC 2kV, Signal 1kV
Surge Immunity EN 61000-4-5
AC: 2kV/1kV
DC: 0.5kV/0.5kV