6130-2200 RV-07B 19” rack system PS-20 – Power card www.westermo.
Legal information The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.
Safety ! Before installation: Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit. This unit should only be installed by qualified personnel. This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only.
Agency approvals and standards compliance Type Approved Agency/ W-mo Safety W-mo Approval / Compliance EN 60950-1, IT equipment Type tests and environmental conditions Electromagnetic Compatibility Phenomena Test Description Test levels Dielectric strength EN 60950 Signal port to other isolated ports 2 kVrms 50 Hz 1 min Power port to other isolated ports 3 kVrms 50 Hz 1 min Power port to other isolated ports with rated power <60 V) 2 kVrms 50 Hz 1 min 500 Vrms 50 Hz 1 min for GND Operating
Declaration of Conformity Westermo Teleindustri AB Declaration of conformity The manufacturer Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden Herewith declares that the product(s) Type of product Model Art no Rack RV-07B 3130-3010 is in conformity with the following EC directive(s). No Short name 2006/95 EC Low Voltage Directive – LVD References of standards applied for this EC declaration of conformity.
Description The RV-07B is a 19" rack which can hold up to 16 Westermo TR-36B modems as well as two PS-20 power supplies. The modem is designed to harsh industrial standards in applications where a number of modems are required in the same location. The rack has passed extensive approvals testing by both Westermo and external test houses, showing the rack can operate in environments with a high level of electromagnetic interference.
Interface specifications Connector P3 Power RV-07B, External DC Power Rated voltage Depending on which card inserted in the slot. Operating voltage Depending on which card inserted in the slot. Rated frequency Depending on which card inserted in the slot. Power consumption Depending on which card inserted in the slot.
Connector X3,X4 Relay Alarm indication Power port 3kVrms 50 Hz 1 min Signal ports 2kVrms 50 Hz 1 min Screw connector 0.2 – 2.
RV-07B with TR-36B RS-422/485* Electrical specification Data rate Data format Protocol Retiming Turn around time Circuit type Transmission range Settings Protection Isolation to Connection Connector size Shielded cable RS-232* Electrical specification Data rate Data format Protocol Retiming Circuit type Transmission range Isolation to EIA RS-485 2-wire or 4-wire twisted pair 300 bit/s to 115.
LED indicator 2 4 3 2 1 1 4 3 2 1 L L N N Protective earth Fault relay see page 7 3-pos Power 1 Direction* Description Product marking PE In Protective earth 2 In AC: Neutral, DC: –Voltage N 3 In AC: Line, DC: + Voltage L * Direction relative this unit.
9-pos D-sub 1 Direction* Description Out Data Carrier Detect (DCD) 2 Out Received Data (RD) 3 In Transmitted Data (TD) 4 In Data Terminal Ready (DTR) 5 – Signal Ground (SG) 6 Out Data Set Ready (DSR) 7 In Request To Send (RTS) 8 Out Clear To Send (CTS) 9 Out Ring Indicator (RI) 9-pos RS-422/485/ PSTN/ Leased line 1 Direction* Product marking Description In R+ (EIA RS-485 A’) R+ 2 In R– (EIA RS-485 B’) R– 3 In/Out T+ (EIA RS-485 A) T/R+ 4 In/Out T– (EIA RS-485 B)
Public Switched Telephone Network (PSTN) Electrical specification Public Switched Telephone Network Data rate 300 bit/s to 33.6 kbit/s Protocol B103, B212, V21, V22, V22B, V23C, V32, V32B, V34 Circuit type TNV-3 Isolation to Power port PSTN line Leased line RS-422/485 RS-232 Connection Screw connector Connector size 0.2 – 2.5 mm2 (AWG 24 – 12) Shielded cable Not required Leased Line (LL) Electrical specification 2- or 4-wire Leased Line Data rate 300 bit/s to 33.
Description PS-20 – Power card The PS-20 is a 90-254 VAC power supply designed to power the RV-07 and the RV-07B racks. The power supply is designed to harsh industrial standards in applications where a number of modems are required in the same location. The rack has passed extensive approvals testing by both Westermo and external test houses, showing the rack can operate in environments with a high level of electromagnetic interference.
Type tests and environmental conditions Electromagnetic Compatibility Phenomena Test Description CE EN 50082-1 Emission EN 55011 Emission Class B EN 61000-6-2 Immunity Class 3 EN 61000-4-2 Immunity EN 61000-4-3 Immunity EN 61000-4-4 Immunity EN 61000-4-5 Immunity EN 61000-4-6 Immunity EN 61000-4-11 Immunity EN 60950 Safety Protection Class 1 Input-output 4,3 kV DC Input-PE 2,2 kV DC Output-PE 0,7 kV DC CE CE Test levels UL1950 High voltage test UL EN 60950 1950 E 1538
Mounting /Removal Before mounting or removing the unit: This unit has one separate protective earthing terminal (marked with “symbol”), while the unit is provided with two mains supply connectors. The grounding terminal of these mains supply connectors is a functional earthing point only Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supplies and all other electrical connections.
Westermo Teleindustri AB • SE-640 40 Stora Sundby, Sweden Phone +46 16 42 80 00 Fax +46 16 42 80 01 E-mail: info@westermo.se Westermo Web site: www.westermo.com Westermo Data Communications AB Svalgången 1 SE-724 81 Västerås Phone: +46 (0)16 42 80 00 • Fax: +46 (0)21 35 18 50 info.sverige@westermo.se Westermo Data Communications Ltd Talisman Business Centre • Duncan Road Park Gate, Southampton • SO31 7GA Phone: +44(0)1489 580-585 • Fax.:+44(0)1489 580586 E-Mail: sales@westermo.co.