User guide

9
6614-2202
Leased Line (LL)
Electrical specification 2- or 4-wire Leased Line 
Data rate 300 bit/s – 33.6 kbit/s 
Protocol B103,B212,V21,V22,V22B,V23C,V23HDX,V23FDX,V32,
V32B,V34
Transmission range/ Budget PSTN 30 dB 
Leased line 40 dB
Protection Installation Fault Tolerant (up to ±60 V) 
Isolation to Power port 
PSTN line 
RS-232  
RS-485
3 kV
rms 50 Hz 1 min 
2 kV
rms 50 Hz 1 min 
2 kV
rms 50 Hz 1 min 
2 kV
rms 50 Hz 1 min
Connection Detachable screw terminal
Shielded cable Not required
RS-422/485 
Electrical specification EIA/TIA-485 ITU V.112-wire or 4-wire twisted pair
Data rate 1200 bit/s – 115.2 kbit/s 
Data format 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits,
Σ 9–12 bits 
Protocol Transparent 
Retiming Yes 
Turn around time <10 µs (half duplex)
Transmission range 1200 m,depending on data rate and cable type (EIA RS-485)
Settings 120 Wtermination and failsafe biasing 680 W
Protection Installation Fault Tolerant (up to ±60 V) 
Isolation to
Power port 3 kV
rms 50 Hz 1 min
PSTN line 2 kV
rms 50 Hz 1 min
Leased line 2 kV
rms 50 Hz 1 min
Connection Detachable screw terminal 
Shielded cable Not required* 
Miscellaneous Do not connect RS-232 and RS-422/485 simultaneously
* To minimise the risk of interference,a shielded cable is recommended when the cable is located inside 3 m 
boundary to the rails and connected to this port.  
The cable shield should be properly connected (360°) to an earthing point within 1 m from this port.This earth-
ing point should have a low impedance connection to the conductive enclosure of the apparatus cabinet,or 
similar,where the unit is built-in.This conductive enclosure should be connected to the earthing system of an 
installation and may be directly connected to the protective earth.