User guide

11
6614-2202
4
3
2
1
4
3
2
1
Leased Line
PSTN
RS-422/485
RS-232
LED Status Indicators
Connections 
TR-36
Jack socket 
Power
Position Direction* Description Product  
marking
1 In AC: Neutral 
DC:– Voltage
2 In AC: Line 
DC:+ Voltage
To minimise the risk of interference,a shielded cable is recommended when the cable is located inside 3 m 
boundary to the rails and connected to this port.  
The cable shield should be properly connected (360°) to an earthing point within 1 m from this port.This earth-
ing point should have a low impedance connection to the conductive enclosure of the apparatus cabinet,or 
similar,where the unit is built-in.This conductive enclosure should be connected to the earthing system of an 
installation and may be directly connected to the protective earth.
PSTN
Position Direction* Description
Screw terminal*
2 In/Out PSTN Transmit/ Receive 
1 In/Out PSTN Transmit/ Receive 
* The PSTN screw terminals are shared with 2-wire Leased line