User guide

10
6614-2202
RS-232 
Electrical specification EIA/TIA-232
Data rate 1 200 bit/s – 115.2 kbit/s
Data format 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits;
Σ 9–12 bits
Protocol Transparent
Retiming Yes
Transmission range Cable length 15 m
Isolation to
Power port 3 kV
rms 50 Hz 1 min
PSTN line 2 kV
rms 50 Hz 1 min
Leased line 2 kV
rms 50 Hz 1 min
Connection 9-pin D-sub female (DCE) and Detachable screw terminal 
(DCE )
Connector size Detachable screw terminal  0.2 – 2.5 mm
2
 (AWG 24 – 12) 
Shielded cable Not required* 
Conductive housing Isolated to all other circuits 
Miscellaneous Do not connect RS-232 and RS-422 / 485 simultaneously
* To minimise the risk of interference,a shielded cable is recommended when the cable is located inside 3 m 
boundary to the rails and connected to this port.  
The cable shield should be properly connected (360°) to an earthing point within 1 m from this port.  
This earthing point should have a low impedance connection to the conductive enclosure of the apparatus  
cabinet, or similar,where the unit is built-in.This conductive enclosure should be connected to the earthing  
system of an installation and may be directly connected to the protective earth.