6651-2231 ODW-720-F2 Fibre Optic Modem Industrial Converter RS-232 to Fibre Optic Link. Repeater, line and redundant ring www.westermo.
Legal information The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.
Safety ! ! ! Before installation: Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit. This unit should only be installed by qualified personnel. This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only.
Note. Fibre Optic Handling Fibre optic equipment requires careful handling as the fibre components are very sensitive to dust and dirt. If the fibre is disconnected from the modem, the protective plug on the transmitter/receiver must be replaced. The protective plug must be kept on during transportation. The fibre optic cable must also be protected in the same way. If this recommendation is not followed, it can jeopardise the warranty.
ATEX Information (Applicable for ODW-720-F2 Ex only) General This unit is intended for use in Zone 2 hazardous location only. Marking II 3 G Ex nA IIC T4 Gc SPECIAL CONDITION WARNING – DO NOT SEPARATE WHEN ENERGIZED Indicate that this unit complies with relevant European standards that are harmonised with the 94/9/EC Directive (ATEX). II 3 G Ex nA IIC T4 Gc SPECIAL CONDITION 6651-2231 Equipment group II.
Ratings Power Ambient temperature Ingress protection (IP) Maximum surface temperatur (12 – 48) VDC; 400 mA –40ºC ≤ Ta ≤ +60ºC IP21 135ºC (temperature class T4) Safety Control Drawing Degree of protection Ambient temperature Installation spacing IP 21 –40°C to +60°C Minimum 25 mm above / below Minimum 10 mm left / right Direction relative this unit! Position 1 2 3 FP Descripton In & out / Relay contact (NO) In & out / Relay contact (C) In & out / Relay contact (NC) Input / Output values Uin = 60 VDC m
SPECIAL CONDITION FOR SAFE USE Ambient temperature: This unit is designed for use in extreme ambient temperature conditions as follows: –40 ºC ≤ Ta ≤ +60 ºC Installation in an apparatus cabinet: This unit requires installation in an Ex certified apparatus cabinet suitable for the area of use and providing a degree of protection of at least IP54. Resistance to impact: This unit requires installation in an apparatus cabinet where adequate resistance to impact is provided by the apparatus cabinet.
Declaration of Conformity Westermo Teleindustri AB Declaration of conformity The manufacturer Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden Herewith declares that the product(s) Type of product Model Art no Industrial fiberoptic repeaters/media converters ODW-700 series 3651-07xx ODW-700EX series 3651-37xx is in conformity with the following EC directive(s).
Type tests and environmental conditions Electromagnetic Compatibility Phenomena Test ESD EN 61000-4-2 RF field AM modulated IEC 61000-4-3 RF field 900 MHz Fast transient ENV 50204 EN 61000-4-4 Surge EN 61000-4-5 RF conducted EN 61000-4-6 Pulse Magnetic field Voltage dips and interruption EN 61000-4-9 EN 61000-4-11 Mains freq. 50 Hz Mains freq.
Functional description Switches LED’s POWER +VA +VB COM O V P Internal Electronics COM STATUS ODW-720 O V P NO C NC RS -232 DCD RD TD SG DSR RTS CTS SHIELD CH 1 OVP Over Voltage Protection OCP Over Current Protection SFP Fibre transceiver TX RX SFP Fibre transceiver TX RX CH 2 Converter serial interface – optical fibre ODW-720 is a fibre optic modem that converts between electrical RS-232 and a fibre optical link.
Interface specifications Power Rated voltage Operating voltage Rated current Rated frequency Inrush current I²t Startup current* Polarity Redundant power input Isolation to Connection Connector size Shielded cable ODW-720-F2: 12 to 48 VDC and 24 VAC ODW-720-F2 Ex: 12 to 48 VDC ODW-720-F2: 10 to 60 VDC and 20 to 30 VAC ODW-720-F2 Ex: 10 to 60 VDC 400 mA @ 12 V 250 mA @ 24 V 100 mA @ 48 V ODW-720F2: DC and 48 to 62 Hz ODW-720-F2 Ex: DC 0.2 A²s 1.
RS-232 Electrical specification Data rate Protocol Data format Data retiming Transmission range Isolation to Connection Shielded cable Conductive housing EIA RS-232 300 bit/s – 250 kbit/s Asynchronous or synchronous 9 – 12 bits in asynchronous mode Any type in synchronous mode Asynchronous mode only 15 m Status and Power port 9-pin D-sub female (DCE) Not required, except when installed in railway applications as signalling and telecommunications apparatus and located close to rails* Isolated to all other
FX (Fibre) Fibre connector Fibre type Wavelength nm, connector 1 Wavelength nm, connector 2 Transmitter Output optical power min/max Receiver Input sensitivity, max Receiver Input optical power, max Optical power budget, worst-case Bit error rate (BER) Transceiver type Laser class * ** *** Bi-di LC-40 LC Simplex Singlemode 9/125 μm Bi-di LC-20 LC Simplex Singlemode 9/125 μm Tx 1310, rx 1550 Tx 1550, rx 1310 –8/0 dBm** Tx1310, rx 1550 TX 1550, rx 1310 –14/8 dBm** Bi-di MM LC-2 LC Simplex Multimode 62.
Location of Interface ports, LED’s and DIP-switches ODW-720-F2 LED Indicators (for details see page 15) DIP-switches accessible under lid (for details see page 16–18) Status screw terminal Position 1 2 3 Description Contact with C when fibre optical links are in operation Common Open (no contact with C) when fibre optical links are not in operation Product marking NO C NC Power screw terminal FX(Fibre) (for details see page 12–13) Position Direction* 1 In 2 3 4 In In In Description Common volta
LED indicators LED Status Description PWR ON Power is on. OFF Power is off. ON Focal point OFF Redundant ring member or multidrop unit. ON Fiber link to other unit has been established at CH 2. Flashing Optical power detected but link to other unit has not been established at CH 2. OFF No optical power detected and no link to other unit has been established at CH 2. ON Fiber link to other unit has been established at CH 1.
! DIP-switch settings Before DIP-switch settings: Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap) Note: Disconnect power before DIP-switch settings. S1 S2 S1 DIP-switch, asynchronous mode speed selection ON ON 1 2 3 4 5 6 7 8 300 bit/s ON 1 2 3 4 5 6 7 8 ON 38.4 kbit/s ON 1 2 3 4 5 6 7 8 1200 bit/s ON 1 2 3 4 5 6 7 8 ON 57.6 kbit/s ON 1 2 3 4 5 6 7 8 2400 bit/s 115.
S1 DIP-switch, synchronous mode time frame selection ON ON 1 2 3 4 5 6 7 8 1.6 ms 1 2 3 4 5 6 7 8 ON ON 26 μs 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 416 μs 1 2 3 4 5 6 7 8 ON ON 13 μs 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 208 μs 1 2 3 4 5 6 7 8 ON 2.6 μs 2.1 μs ON 8.6 μs 1 2 3 4 5 6 7 8 2 μs ON 1 2 3 4 5 6 7 8 104 μs 1 2 3 4 5 6 7 8 ON 4.
S2 DIP-switch ON ON CTS always active. Use secondary data channel.* 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ON ON Transport RTS to CTS.* 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ON ON Multidrop mode. 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ON ON Redundant ring mode. 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Multidrop mid unit or Redundant ring member. ON Multidrop end unit. Redundant ring focal point. ON 1 2 3 4 5 6 7 8 Single channel system redundant ring. E.g.
About the interfaces Power The power terminal has two independent inputs, +VA and +VB, allowing redundant power input. The ODW-720-F2 power supply is galvanically isolated from all other interfaces. Optical fibre interfaces ODW-720-F2 uses Small Form Factor Pluggable (SFP) transceivers. This means that a wide range of different fibre transceivers and connectors can be used (see page 12–13). RS-232 interface The RS-232 interface is a female 9-position D-sub.
Mounting This unit should be mounted on 35 mm DIN-rail, which is horizontally mounted inside an apparatus cabinet, or similar. Snap on mounting, see figure. CLICK! CLICK! Cooling This unit uses convection cooling. To avoid obstructing the airflow around the unit, use the following spacing rules. Minimum spacing 25 mm (1.0 inch) above /below and 10 mm (0.4 inches) left /right the unit. Spacing is recommended for the use of unit in full operating temperature range and service life. 10 mm * (0.
Referring documents For detailed information on how to configure the ODW-720-F2 for different applications.
Westermo Teleindustri AB • SE-640 40 Stora Sundby, Sweden Phone +46 16 42 80 00 Fax +46 16 42 80 01 E-mail: info@westermo.com Westermo Web site: www.westermo.com United Kingdom Westermo Data Communications Ltd Talisman Business Centre • Duncan Road Park Gate, Southampton • SO31 7GA Phone: +44(0)1489 580‑585 • Fax.:+44(0)1489 580586 E-Mail: sales@westermo.co.uk Germany Westermo Data Communications GmbH Goethestraße 67, 68753 Waghäusel Tel.: +49(0)7254-95400-0 • Fax.:+49(0)7254-95400-9 E-Mail: info@westermo.