Specifications
conductorpinassignmentshowsasfollowingtableforyourreference.
RJ‐45conductor TypeofSignal Polarityofpower Note
1 RxD+ V‐ Alternative‐A
2 RxD‐ V‐ Alternative‐A
3 TxD+ V+ Alternative‐A
6 TxD‐ V+ Alternative‐A
Note:ThePDdeviceshouldacceptpower fromeither1,2,3,6(datapairs)or4,5,7,8
(sparepairs);forthedetailinformation,pleaserefertoIEEE802.3at/IEEE802.3afPower
overEthernetstandard.
GigabitEthernet/SFPcomboport
ThePMI‐110‐F2Gprovides2GigabitRJ‐45/SFPcomboportsthatwithdifferentlink
speed–10Mbps,100Mbps,1000Mbps,andcompliantwiththestandardsofIEEE802.3
10Base‐T,IEEE82.3u100Base‐TX,IEEE8023.u100Base‐FX,IEEE802.3ab1000Base‐T, and
IEEE802.3zGigabitfiber.
ThecomboportssupportSFPtransceiverplug‐inhighpriorityfunction;thus,don’t
connectEthernetRJ‐45andinsertSFPtransceiveratthesametime;itwillcausetheport
beingactivatedinwrongstatus.
TheSFPportsalsoprovideDigitalDiagnosticMonitoringfunction,itcanassistuserto
monitorthequalityofopticalsignal,anddiagnosethetransmissionoffiber.Thisfunction
isonlyavailableforWestermorecomendedDDMSFPtransceiver,anddoesnotsupport
thirdpartytransceiverthatmaynotfullycomplywithMSASFPtransceiverstandard.
BytheDDMfunction,usercangetrealinformationincludingthestrengthofreceived
opticalsignal,launchedopticalsignalandcurrentoperatingtemperatureofSFP
transceiver,andthespecificationoftransceiver.
ThefollowingdiagramshowstheinformationcapturedfromWEBuserinterface.
Range:thespecificationofWestermodefined.
Current:actualvaluereadfromSFPtransceiver.
TxPower(dBm):opticalstrengthofreceived.
RxPower(dBm):opticalstrengthoflaunched.
Note:TheEthernetSwitchhastouseULrecognizedfibertransceiverwithClass1Laser/LEDDiode.
Note:Itisrecommendedtonotplug‐inSFPfibertransceiverandlinkupRJ‐45portatthesametime,it
mightcausetheconnectiondoesnotworkingproperly.
16