Type tests and environmental conditions
Phenomena Test Description Test levels
ESD EN 61000-4-2 Enclosure contact ± 4 kV (crit A)
Enclosure air ± 8 kV (crit A)
RF field AM modulated IEC 61000-4-3 Enclosure 10 V/m (crit A)
(80 – 2700 MHz)
Fast transient EN 61000-4-4 Signal ports ± 1 kV (crit A)
Power ports ± 2 kV (crit A)
Surge EN 61000-4-5 Ethernet ports ± 1 kV (direct) (crit A)
Power ports
± 0.5 kV (line to earth) (crit A)
± 0.5 kV (line to line) (crit A)
RF conducted EN 61000-4-6 All ports 10 V/m, (crit A)
(0.15 – 80 MHz)
Radiated emission EN 55022 Enclosure Class B
Conducted emission EN 55022 AC power ports Class B
EN 55022 Ethernet ports Class B
Temperature Operating –20 to +60ºC
(–30 to +70ºC restricted operation)
Storage & Transport –40 to +85ºC
Humidity Operating 0 to 90% relative humidity non
condensing.
Storage & Transport 0 to 90% relative humidity non
condensing.
Altitude Operating 2000 m / 70 kPa
Service life Operating 10 year
Dimension W x H x D 103 x 32 x 156 mm
Weight 0.30 kg
Degree of protection IEC 529 Enclosure IP 40
Cooling Convection
Mounting Horizontal on 35 mm DIN-rail